Formulaire de contact

Solutions de chauffage intelligentes Tuyaux de chauffage au sol

PARAMÈTRES DU PRODUIT

Floor Heating Pipes(tuyau en polyéthylène réticulant) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Description
Demander un devis

Description

Présentation de Floor Heating P.IPS

Floor Heating Pipes(tuyau en polyéthylène réticulant) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).

Details of Floor Heating Pipes

we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:

Temperature tolerance: -70℃~110℃ working range

(instant temperature resistance up to 130℃)

Pressure performance: PN10 rated pressure 95℃ hot water long-term operation

Memory effect: Unique shape recovery features to avoid permanent creases

Résistance à la corrosion: Resistance to acid-base media (pH2-12) and microbial attack

Intergenerational evolution of product technology

 Features First generation PE-RT Second generation PEX-B Third generation PEX-A
 Degree of crosslinking no 65-70%      ≥75%
 Temperature rating Class III Level IV Level V
 Coefficient of thermal expansion 0.18 mm/m ℃ 0.15 mm/m ℃ 0.12 mm/m ℃
 Burst pressure (95 °C) 5.2 MPa 6.8 MPa 8.4 MPa

* Note: Data in this table are based on ISO15875 international standard test environment *

Spécifications de Floor Heating P.IPS 

Standard pipe parameter matrix

Specification and modelOutside diameter (mm)Wall thickness (mm)SDR valuePressure ratingLength of applicable loop
PEX – 16 x 2.0162.08.0S4≤80m
PEX – 20 x 2.3202.38.7S3.2≤100m
PEX-25×2.8(enhanced)252.88.9S2.5≤120m

DTS (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe

Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)

Conductivité thermique: 0.38W/(m·K) (30% better than copper pipe)

Analysis of multi-layer composite structure

Five-layer co-extrusion process:

1. Inner layer: PEX-A antibacterial layer (silver ion coating)

2. Bonding layer: modified polyethylene

3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)

4. Reinforcing layer: glass fiber reinforced PEX

5. Outer layer: anti-UV modified layer

Engineering grade product advantages

Laboratory verification data

Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)

Long-term hydrostatic strength: ≥50 years of life at 95℃/1.0MPa (ASTM F876)

Bending fatigue test: no crack at 10000 bending radius 5D cycles

Intelligent heating solution

mermaid

graph TD

UN[heat source system] –> B[PEX diversity collector]

B –> C[PEX main pipe DN32]

C –> D[PEX floor heating coil DN16/20]

D –> E[Système de contrôle intelligent de la température]

E –> F[mobile APP remote management]

Applications de Floor Heating P.IPS

Civil construction field

Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm

Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%

Commercial engineering cases

Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm

Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system

Special industrial applications

Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer

Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining

Global Certification System

Drinking water safety: NSF/ANSI 61, KTW (Germany)

Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Germany)

Environmental certification: Blue Angel (Blue Angel), LEED plus

Emballage et expédition

Cela dépend des produits et de la quantité,nous pourrions faire l'emballage du bobinage,rouleaux,emballage en paquet,caisses ou boîtes,etc..

Expédition:Par la mer,chemin de fer,par avion ou comme demande du client.

Profil de l'entreprise

Luoyang Datang Energy Tech Co.Ltd a été créée en 2015 et situé dans une zone de développement de haute technologie, Ville de Luoyang, couvre une vaste zone avec des installations de pointe. Notre gouvernement offre un environnement favorable, y compris un transport pratique et un accès aux ressources essentielles. Depuis sa création en 2015, nous nous sommes engagés à l'excellence dans les tuyaux et raccords, innover continuellement pour répondre aux demandes du marché.

Si vous avez besoin de tuyaux et raccords PPR,N'hésitez pas à contacter nous(sales@pipesandfittings.net)

Conditions de paiement

T/T,L/C à vue,Western union & Paypal,etc..

FAQ de Floor Heating P.IPS

Q: How to choose PEX pipe and aluminum-plastic pipe?

UN: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 contre 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).

Q: Floor heating pipe spacing design specification?

UN: According to EN1264 standard:

Conventional area: 200mm spacing (pipe diameter 16mm)

Edge area: 150mm encryption area (extending 1.5m to external wall)

Bathroom: 175mm spacing + border insulation tape

DEMANDER UN DEVIS