Foirm Teagmhála

Cast Iron Swing Check Valve | Flanged Non Return Valve DN50-DN600 | PN10/PN16 | BS GA 12334

Paraiméadair TÁIRGÍ

Bolts & Nuts Carbon Steel Zinc Plated / SS304 / SS316 (Roghnach)
Gasket PTFE
Seal Type EPDM Soft Seal (0°C go +80°C) / Metal Seal (-10°C to +350°C)
Coating Fusion-Bonded Epoxy Coating (FBE)
Applicable Media Uisce, Wastewater, Ola, Gás, Mild Chemicals
Feidhmchláir Drinking Water, Draenáil, Wastewater, Uisciúcháin, HVAC, Cosaint Dóiteáin, Ceimiceach & Energy
Certification ISO 9001
Customization OEM, ODM, OBM
Cur síos
IARRATAS A CHUID

Cur síos

Forbhreathnú Táirge

Tá anCast Iron Swing Check Valve is a reliable, automatic non-return valve designed to prevent reverse flow in water, wastewater, agus córais píobaireachta tionsclaíochta. Featuring a robust cast iron or ductile iron body with a hinged disc that swings freely on a pin, this valve opens with forward flow and closes automatically when flow stops or reverses — protecting pumps, comhbhrúiteoirí, and other equipment from damaging backflow. Available with EPDM soft seal (0°C go +80°C) for bubble-tight shut-off or metal-to-metal seal (-10°C to +350°C) for high-temperature applications. The flanged ends conform to BS EN 1092-2:1997 caighdeáin, ensuring compatibility with international piping systems. With sizes from 2″ to 24″ (DN50 to DN600) and pressure ratings PN10/PN16, this valve is suitable for a wide range of applications including drinking water, soláthar uisce & draenáil, wastewater treatment, uisciúcháin, HVAC, fire protection, and chemical & energy industries. The fusion-bonded epoxy coating provides superior corrosion protection for long service life. With OEM/ODM customization support, it is the trusted choice for engineers and plant operators worldwide.

Cast iron swing check valve

Sonraíochtaí Teicniúla

ParaiméadarSonraíocht
Ainm Táirge Cast Iron Swing Check Valve
Caighdeán Dearaidh BS GA 12334, DIN3202 F6, BS1868, ASME B16.34, API 6D
Connection Standard BS GA 1092-2:1997 / DIN2533 / ASME B16.5
Face-to-Face ASME B16.10 / DIN3202-F6
Testing Standard API 598 / API 6D / DIN3230
Raon Méid 2″ – 24″ (DN50 – DN600)
Rátáil BrúPN10 / PN16
Ábhar CoirpIarann ​​Teilgthe / Iarann ​​insínte (GGG40/GGG50)
Ábhar Diosca Iarann ​​insínte + EPDM (Soft Seal) / Cruach Dhosmálta 304/316 (Metal Seal)
Seat Ring Brass HPb59-1
Hinge Pin SS420 / SS304 / SS316 / SS416 / SS431

Cast iron swing check valve

Príomhghnéithe

  1. Swing Check Design – Low Pressure Drop
  2. Dual Seal Options – Soft Seal & Metal Seal
  3. Robust Ductile Iron Disc – Durable & Corrosion Resistant
  4. Fusion-Bonded Epoxy Coating – Superior Corrosion Protection
  5. BS GA 12334 Compliant – International Standard
  6. Wide Temperature Range – -10°C to +350°C

Prionsabal Oibre

The swing check valve operates through a simple yet reliable mechanism:

  • 1. Forward Flow (Valve Open): When upstream pressure exceeds downstream pressure, the disc swings open on its hinge pin, allowing flow to pass through with minimal resistance.
  • 2. Reverse Flow or Stop (Valve Closed): When flow stops or reverses, gravity and backflow pressure cause the disc to swing back onto the seat, creating a tight seal.
  • 3. Horizontal Installation: Swing check valves must be installed horizontally (or in slightly sloping lines) to allow gravity to assist in closing the disc.

Cast iron swing check valve

Feidhmchláir

  1. Soláthar Uisce & Dáileadh
  2. Wastewater Treatment
  3. Córais Cosanta Dóiteáin
  4. Industrial Process Lines

Pacáil agus Loingsiú

Braitheann an pacáil ar an gcineál táirge agus ar chainníocht an táirge. Options include wooden crates or carton boxes with proper protection for flange faces. Is féidir an loingsiú a shocrú ar muir, iarnród, aer, nó de réir iarratais an chustaiméara.

Próifíl na Cuideachta

Tá Luoyang Datang Energy Tech Co., Teo Is soláthraí comhla tionsclaíoch gairmiúil, dedicated to providing reliable flow control solutions for water treatment, HVAC, fire protection, agus córais píobaireachta tionsclaíochta ar fud an domhain. All products are manufactured to international standards with ISO 9001 deimhnithe. Le breis 10 blianta de thaithí, áis nua-aimseartha de 80,000 m², agus 200+ fostaithe gairmiúla, déanaimid freastal ar chustaiméirí i 10+ tíortha le táirgí ardchaighdeáin, praghsáil iomaíoch, agus seachadadh iontaofa.

Cast iron swing check valve

Téarmaí Íocaíochta

T/T, L/C ag radharc, Aontas Iarthar, PayPal, Apple Pá, Google Pay, Cárta Creidmheasa, srl.

CCanna | Frequently Asked Questions

C1: Can a swing check valve be installed vertically?

A: Níl. Swing check valves must be installed horizontally (or in slightly inclined piping) because gravity is required for the disc to return to the seat when flow stops. Vertical installation prevents the disc from closing completely, resulting in backflow.

C2: What is the difference between soft-seated and metal-seated valves?

A: Soft-seated (EPDM) valves provide zero-leakage (bubble-tight) shut-off and operate within a temperature range of 0°C to +80°C; they are suitable for water, sewage, agus ceimiceáin éadroma. Metal-seated (metal-to-metal) valves operate between -10°C and +350°C and are suitable for steam, high-temperature fluids, and abrasive media, though they have a slightly higher leakage rate (Class IV).

C3: What is the maximum working pressure for this valve?

A: The standard configuration supports a maximum working pressure of PN10/PN16. Higher pressure ratings are available upon request; please contact our sales team for more information.

C4: What is the difference between a swing check valve and a lift check valve?

A: Swing check valves use a disc that swings on a hinge; they offer low pressure drop (thart. 0.5 psi), must be installed horizontally, and are suitable for large-bore and low-pressure-drop applications. Lift check valves use a disc that lifts vertically; they offer superior sealing but have a higher pressure drop and can be installed either vertically or horizontally.

Cast iron swing check valve

IARRATAS A CHUID

IARRATAS A CHUID