LUOYANG CAME ENERGY TECH CO., LTD

High Quality Crosslinking Polyethylene Pipe
PRODUCT PRAMETERS
Kev piav qhia
Introduction of High Quality Crosslinking Polyethylene Pib ip
PEX (Cross-linked Polyethylene) cross-linked polyethylene pipe is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Details of High Quality Crosslinking Polyethylene Pib ip
we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:
Temperature tolerance: -70℃~110℃ working range
(instant temperature resistance up to 130℃)
Pressure performance: PN10 rated pressure 95℃ hot water long-term operation
Memory effect: Unique shape recovery features to avoid permanent creases
Corrosion kuj: Resistance to acid-base media (pH2-12) and microbial attack
Intergenerational evolution of product technology
| Features | First generation PE-RT | Second generation PEX-B | Third generation PEX-A |
| Degree of crosslinking | no | 65-70% | ≥75% |
| Temperature rating | Class III | Level IV | Level V |
| Coefficient of thermal expansion | 0.18 mm/m ℃ | 0.15 mm/m ℃ | 0.12 mm/m ℃ |
| Burst pressure (95 ° C) | 5.2 MPa | 6.8 MPa | 8.4 MPa |
* Nco tseg: Data in this table are based on ISO15875 international standard test environment *
Specifications of High Quality Crosslinking Polyethylene Pib ip
Standard pipe parameter matrix
| Specification and model | Sab nraud txoj kab uas hla (mm) | Wall thickness (mm) | SDR tus nqi | Pressure rating | Length of applicable loop |
| PEX – 16 x 2.0 | 16 | 2.0 | 8.0 | S4 | ≤80m |
| PEX – 20 x 2.3 | 20 | 2.3 | 8.7 | S3.2 | ≤100m |
| PEX-25×2.8(enhanced) | 25 | 2.8 | 8.9 | S2.5 | ≤120m |
SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe
Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)
Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)
Analysis of multi-layer composite structure
Five-layer co-extrusion process:
1. Inner layer: PEX-A antibacterial layer (silver ion coating)
2. Bonding layer: modified polyethylene
3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)
4. Reinforcing layer: glass fiber reinforced PEX
5. Outer layer: anti-UV modified layer
Engineering grade product advantages
Laboratory verification data
Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)
Lub sij hawm ntev hydrostatic zog: ≥50 years of life at 95℃/1.0MPa (ASTM F876)
Bending fatigue test: no crack at 10000 bending radius 5D cycles
Intelligent heating solution
mermaid
graph TD
A[heat source system] –> B[PEX diversity collector]
B –> C[PEX main pipe DN32]
C –> D[PEX floor heating coil DN16/20]
D –> E[Intelligent temperature control system]
E –> F[mobile APP remote management]
Applications of High Quality Crosslinking Polyethylene Pib ip
Civil construction field
Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm
Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%
Commercial engineering cases
Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm
Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system
Special industrial applications
Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer
Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining
Global Certification System
Drinking water safety: NSF/ANSI 61, KTW (Lub teb chaws Yelemees)
Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Lub teb chaws Yelemees)
Environmental certification: Blue Angel (Blue Angel), LEED plus
Packing thiab Shipping
Nyob ntawm cov khoom thiab qty,peb tuaj yeem ua qhov ntim ntawm coiling,yob,pob khoom,thawv los yog thawv,lwm.
Kev xa khoom:Los ntawm hiav txwv,txoj kev tsheb ciav hlau,los ntawm huab cua los yog raws li cov neeg siv khoom thov.
Tuam txhab Profile
Luoyang Datang Energy Tech Co. Ltd yog tsim nyob rau hauv 2015 thiab nyob rau hauv High-tech development zone, Lub nroog Luoyang, npog thaj tsam loj nrog cov chaw ua haujlwm hauv lub xeev. Peb tsoom fwv muab kev txhawb nqa ib puag ncig, suav nrog kev thauj mus los yooj yim thiab nkag mus rau cov peev txheej tseem ceeb. Txij li thaum pib hauv 2015, peb tau cog lus rau kev ua tau zoo hauv cov kav dej thiab fittings, tsis tu ncua innovating kom tau raws li kev lag luam xav tau.
Yog tias koj xav tau PPR Pipes thiab Fittings,Thov koj xav tiv tauj peb(sales@pipesandfittings.net)
Cov nqe lus them nqi
T/T,L/C thaum pom,Western Union & Paypal,lwm.
FAQ ntawm High Quality Crosslinking Polyethylene Pipe
Q: How to choose PEX pipe and aluminum-plastic pipe?
A: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).
Q: Floor heating pipe spacing design specification?
A: According to EN1264 standard:
Conventional area: 200mm spacing (pipe diameter 16mm)
Edge area: 150mm encryption area (extending 1.5m to external wall)
Bathroom: 175mm spacing + border insulation tape
THOV QHIA