Fòm kontak

Intelligent Heating Solutions Floor Heating Pipes

PARAMÈT PWODWI

Floor Heating Pipes(crosslinking polyethylene pipe) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Deskripsyon
Mande Yon Quote

Deskripsyon

Entwodiksyon de Floor Heating Pipes

Floor Heating Pipes(crosslinking polyethylene pipe) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).

Details of Floor Heating Pipes

we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:

Temperature tolerance: -70℃~110℃ working range

(instant temperature resistance up to 130℃)

Pressure performance: PN10 rated pressure 95℃ hot water long-term operation

Memory effect: Unique shape recovery features to avoid permanent creases

Corrosion resistance: Resistance to acid-base media (pH2-12) and microbial attack

Intergenerational evolution of product technology

 Features First generation PE-RT Second generation PEX-B Third generation PEX-A
 Degree of crosslinking no 65-70%      ≥75%
 Temperature rating Class III Level IV Level V
 Coefficient of thermal expansion 0.18 mm/m ℃ 0.15 mm/m ℃ 0.12 mm/m ℃
 Burst pressure (95 °C) 5.2 MPa 6.8 MPa 8.4 MPa

* Note: Data in this table are based on ISO15875 international standard test environment *

Specifications of Floor Heating Pipes 

Standard pipe parameter matrix

Specification and modelOutside diameter (mm)Wall thickness (mm)SDR valueEvalyasyon presyonLength of applicable loop
PEX – 16 x 2.0162.08.0S4≤80m
PEX – 20 x 2.3202.38.7S3.2≤100m
PEX-25×2.8(enhanced)252.88.9S2.5≤120m

SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe

Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)

Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)

Analysis of multi-layer composite structure

Five-layer co-extrusion process:

1. Inner layer: PEX-A antibacterial layer (silver ion coating)

2. Bonding layer: modified polyethylene

3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)

4. Reinforcing layer: glass fiber reinforced PEX

5. Outer layer: anti-UV modified layer

Engineering grade product advantages

Laboratory verification data

Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)

Long-term hydrostatic strength: ≥50 years of life at 95℃/1.0MPa (ASTM F876)

Bending fatigue test: no crack at 10000 bending radius 5D cycles

Intelligent heating solution

mermaid

graph TD

A[heat source system] –> B[PEX diversity collector]

B –> C[PEX main pipe DN32]

C –> D[PEX floor heating coil DN16/20]

D –> E[Intelligent temperature control system]

E –> F[mobile APP remote management]

Applications of Floor Heating Pipes

Civil construction field

Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm

Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%

Commercial engineering cases

Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm

Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system

Special industrial applications

Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer

Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining

Global Certification System

Drinking water safety: NSF/ANSI 61, KTW (Germany)

Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Germany)

Environmental certification: Blue Angel (Blue Angel), LEED plus

Anbalaj ak chajman

Depann sou pwodwi yo ak kantite,nou ta ka fè anbalaj la nan bobin,woulo,pake pake,kès oswa bwat,elatriye.

chajman:Pa lanmè,tren,pa lè oswa kòm demann kliyan an.

Konpayi Profile

Luoyang Datang Energy Tech Co.Ltd te etabli an 2015 epi ki sitiye nan zòn devlopman gwo teknoloji, Vil Luoyang, kouvri yon gwo zòn ak enstalasyon dènye modèl yo. Gouvènman nou an ofri yon anviwonman ki bay sipò, enkli transpò pratik ak aksè a resous esansyèl. Depi kreyasyon an 2015, nou te angaje nan ekselans nan tiyo ak ekipman, kontinyèlman inovasyon pou satisfè demann mache.

Si ou bezwen PPR Tiyo ak Fittings,Please feel free to contact us(sales@pipesandfittings.net)

Regleman Peman

T/T,L/C nan je,Western Union & Paypal,elatriye.

FAQ of Floor Heating Pipes

Q: How to choose PEX pipe and aluminum-plastic pipe?

A: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).

Q: Floor heating pipe spacing design specification?

A: According to EN1264 standard:

Conventional area: 200mm spacing (pipe diameter 16mm)

Edge area: 150mm encryption area (extending 1.5m to external wall)

Bathroom: 175mm spacing + border insulation tape

DEMANDE YON PREVO

DEMANDE YON PREVO