Formulir Kontak

Katup Apung Hidraulik Stainless Steel DN50-DN200 Katup Kontrol Level Tangki Air Otomatis

PARAMETER PRODUK

Medium Temperature0°C ~ 80°C
Sealing MaterialEPDM / Rubber
Bahan TubuhBesi Ulet / Cast Iron / Baja Tahan Karat / Cast Steel
Bahan BatangBaja Tahan Karat
Bahan DiskRubber
Custom ServiceOEM Support
Place of OriginCina
Keterangan
PERMINTAAN PENAWARAN

Keterangan

Ikhtisar Produk

Itu Hydraulic Water Level Float Valve is a pilot-operated diaphragm valve designed for automatic water level control in tanks and reservoirs. It integrates a main valve, a regulating needle valve, and a float pilot valve. As the water level changes, the float rises or falls, piloting the main valve to open or close, thereby maintaining a preset water level without the need for external power. This valve features precise control, stable operation, dan umur panjang. Available in a wide range of materials including ductile iron, cast steel, and stainless steel to suit various water quality conditions.

Spesifikasi Teknis

SpesifikasiDetails
Nama ProdukHydraulic Water Level Float Valve
ModelFL100XH-16
StrukturRegulation Valve
KekuatanHydraulic
Nominal DiameterDN20DN800
KoneksiFlens
Peringkat TekananTekanan Rendah (PN10/PN16)
SedangAir

Stainless Steel Hydraulic Float Valve

Fitur Utama

  • Accurate Level Control: The float pilot precisely senses water level changes, ensuring the tank maintains a stable preset level.
  • Hydraulic Drive: Utilizes line pressure for operation, requiring no external electrical power, making it safe and energy-efficient.
  • Durable Materials: Constructed with corrosion-resistant materials such as EPDM seals and stainless steel stems for long-term reliability.
  • Low Maintenance: Simple structure with minimal moving parts reduces failure rates and maintenance costs.
  • Versatile Sizing: Available in sizes from 2 inci ke 10 inci (DN20–DN800) to fit various tank capacities.
  • Customizable Options: Offers OEM services for material, koneksi, and coating to meet specific project requirements.

Aplikasi

  • Water Supply Systems: Automatic water level control in municipal water storage tanks and elevated water towers.
  • Industrial Water Tanks: Maintaining levels in cooling water basins, process water tanks, and fire water storage.
  • Sistem HVAC: Fill water control for closed-loop chilled/hot water expansion tanks.
  • Agricultural Irrigation: Level management in reservoir ponds and irrigation channel head tanks.
  • Proteksi Kebakaran: Maintaining required water levels in fire reserve tanks and roof fire water tanks.

Stainless Steel Hydraulic Float Valve

Pengepakan dan Pengiriman

  • Packing MethodStandard export wooden crates or pallets; rainproof and moisture-proof.
  • PengirimanSupported by sea, kereta api, udara, or road transport to designated ports. Container loading and securing services provided to ensure safe transit.

Ketentuan Pembayaran

  • T/T, L/C pada pandangan, Serikat Barat, PayPal, Kartu kredit, dll..

Profil Perusahaan

Luoyang Datang Energy Tech Co., Ltd adalah pemasok katup industri profesional, didedikasikan untuk menyediakan solusi kontrol aliran yang andal untuk pengolahan air, kimia, minyak & gas, AC, dan sistem perpipaan industri di seluruh dunia. Semua produk diproduksi dengan standar internasional dengan CE dan ISO 9001 sertifikasi. Dengan berakhir 10 pengalaman bertahun-tahun, fasilitas modern 80,000 m², Dan 200+ karyawan profesional, kami melayani pelanggan di 10+ negara dengan produk berkualitas, harga yang kompetitif, dan pengiriman yang dapat diandalkan.

Stainless Steel Hydraulic Float Valve

Pertanyaan Umum

Q1: Can this float valve be used for seawater or corrosive media?
A1: The standard configuration is for fresh water. For seawater or mildly corrosive media, we offer customization with full stainless steel (316L) body and special sealing materials.

Q2: How to select the correct valve size (hari) for my tank?
A2: Size selection is determined by the inlet pipe diameter, required flow rate, and working pressure. Umumnya, the valve size matches the pipeline. Please provide your operating parameters, and our technical team will assist with selection.

Q3: What could cause the valve to fail to close or leak?
A3: Common causes include: 1) Stuck or damaged float; 2) Clogged needle valve; 3) Damaged diaphragm. Regular cleaning of the strainer and inspection of the float movement are recommended. Contact after-sales for a repair kit if the issue persists.

Q4: What is the maximum working temperature?
A4: The standard model operates at 0°C ~ 80°C. For higher temperatures (misalnya, hot water systems), please consult us for high-temperature sealing materials.

Q5: What installation precautions are needed?
A5: 1) Flush the pipeline before installation to prevent debris from entering; 2) Mount the float horizontally inside the tank to ensure free movement; 3) Install a strainer and isolation valve upstream for maintenance access.

Stainless Steel Hydraulic Float Valve

PERMINTAAN PENAWARAN

PERMINTAAN PENAWARAN