Ụlọ ọrụ LUOYANG CAMEENERGY TECH CO., LTD

DC24V Solenoid Valve Hanging Ụdị FM200 Extinguisher Brass Nozzle Valve
PRAMETERS ngwaahịa
Nkọwa
Overview of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve is engineered for superior performance in plumbing, ulo oru, na ngwa azụmahịa. Emere site na enweghị ndu, ọla na-eguzogide corrosion, valvụ ndị a na-eme ka ogologo oge na-adịgide adịgide na njikwa mmiri a pụrụ ịdabere na ya, gas, mmanụ, na mmiri mmiri ndị ọzọ.
Site na nhazi nkenke yana ihe owuwu siri ike, anyị bras valves na-enye ọrụ dị nro, magburu onwe akara, na iguzogide nrụgide dị elu-na-eme ka ha dị mma maka ebe obibi, azụmahịa, na ụlọ ọrụ ọkpọkọ usoro.
Key Features of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
Mwube Brass adịchaghị - enweghị ndu, corrosion na-eguzogide, na inogide
Ngosipụta Ngosipụta Leak - Akara siri ike maka njikwa mmiri echekwara
Nrụgide dị elu & Nguzogide okpomọkụ - arụmọrụ a pụrụ ịdabere na ya n'okpuru ọnọdụ na-achọsi ike
Ọrụ dị nro - Aka dị mfe na-atụgharị maka ngbanwe ziri ezi
Ngwa dịgasị iche iche - Dakọtara na mmiri, gas, mmanụ, na usoro HVAC
Nha otutu & Nhọrọ Njikọ - Dị na ¼” ruo 2″ nha (NPT, eriri BSP)

(DC24V Solenoid Valve Hanging Ụdị FM200 Extinguisher Brass Nozzle Valve)
Specification of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
This brass solenoid valve operates on 24V DC power. It’s the hanging kind made for straight placing onto FM200 fire reductions system cylinders. The shutoff body is solid brass for toughness and deterioration resistance. It regulates the circulation of FM200 snuffing out agent precisely. The nozzle shutoff ensures reputable discharge throughout a fire event.
Installment is simple making use of the hanging bracket. The valve connects directly to the cyndrical tube electrical outlet. This style saves area and simplifies system design. Standard NPT threads give secure pipe connections. The shutoff opens only when its 24V DC coil receives an electric signal. This coil is epoxy-sealed for defense against dampness and dust. The coil offers regular performance with time.
The valve handles details stress. Its maximum working stress is 360 PSI. Proof stress gets to 720 PSI. Burst stress is considerably greater for security. The shutoff runs effectively within a temperature level array. The most affordable temperature is -40 Celsius F. The greatest temperature is 165 Celsius F. The shutoff opening dimension is 0.75 sentimita asatọ. This orifice diameter regulates the FM200 flow price successfully. The shutoff body meets product standards for fire systems. The brass construction makes certain durability and leak-free procedure.
This element carries essential qualifications. It is FM Accepted. It is UL Listed. These authorizations validate the shutoff satisfies stringent safety and security and efficiency criteria. The shutoff is constructed for lengthy service life in demanding atmospheres. Its design reduces inner leakage. It gives a reputable shut-off when closed. This valve is a crucial part of automatic FM200 fire reductions systems. It makes certain the snuffing out representative launches just when required. Appropriate installation and upkeep are essential for ideal function. Constantly adhere to the producer’s directions and regional fire codes.

(DC24V Solenoid Valve Hanging Ụdị FM200 Extinguisher Brass Nozzle Valve)
Applications of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
This brass nozzle valve regulates FM200 gas release in fire reductions systems. It installs suspending. This conserves area in limited setups. The valve uses a 24V DC solenoid. Low voltage operation improves safety. It avoids high voltage risks near delicate electronic devices.
FM200 snuffs out fires quick. It leaves no deposit. This shields useful tools. The shutoff deals with FM200 systems in essential areas. Web server areas require this defense. Information facilities count on it. Telecom centers use it too. Medical equipment spaces benefit. Industrial control panels need it. Tidy representative systems protect against damages from water or powder.
The hanging design streamlines installment expenses. It fits nicely above tools shelfs. Upkeep access stays clear. The brass body stands up to deterioration well. It manages FM200 gas accurately over time. The valve opens instantaneously when signified. This permits quick gas discharge. Quick discharge is vital for fire control.
The 24V DC signal originates from the fire panel. Electrical wiring is simple and risk-free. Electrical contractors mount it quickly. The shutoff integrates with typical discovery systems. It triggers upon verified fire signals. Reliability is vital forever security. This shutoff offers trustworthy performance. It satisfies strict fire safety requirements. Normal testing makes sure preparedness.
Mbukota na mbupu
Dabere na ngwaahịa na qty,anyị nwere ike ịme nkwakọ ngwaahịa,na-apụta,ngwugwu ngwugwu,igbe ma ọ bụ igbe,wdg.
Mbupu:Site n'oké osimiri,ụzọ ụgbọ oloko,site na ikuku ma ọ bụ dị ka ndị ahịa arịrịọ.
Nkọwapụta Ụlọ ọrụ
Ụlọ ọrụ Luoyang Datang Energy Tech Co., Ltd., Ltd. bụ onye na-emepụta ihe na China na-emepụta ọkachamara na ọkpọkọ plastik dị elu na akwa akwa. Ejiri ahịrị mmepụta akpaghị aka nke ọgbara ọhụrụ yana otu ndị otu na-akwado ya 200 ndị ọkachamara, anyị na-enye nnukwu ahịrị ngwaahịa mejupụtara 150 ụdị ọkpọkọ rọba na ihe ndị e mere maka inye mmiri na usoro mmiri mmiri, nnyefe gas, na usoro kpo oku ala. Ngwaahịa anyị bụ isi gụnyere PVC Pipes na Fittings, PE (HDPE) Ọkụ na Ngwakọta, PPR ọkpọkọ na ihe ndozi, na PEX Floor kpo oku ọkpọkọ.
Ọ bụrụ na ị nwere ajụjụ ọ bụla gbasara HDPE Pipe Fitting, biko egbula ịkpọtụrụ anyị!
Tel.:0086-183 3790 0677
Wechat: 0086-183 3790 0677
WhatsApp: 0086-183 3790 0677
Email: sales@pipesandfittings.net
Usoro ịkwụ ụgwọ
T/T,L/C na anya,Western Union & Paypal,wdg.
5 FAQs of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
What does this brass nozzle valve do?
It controls FM200 fire suppressant flow. The valve stays closed normally. It opens when the system needs to discharge gas. This stops fires fast.
Why does it need 24V DC power?
24V DC is standard for fire systems. It’s safe. It’s reliable. The power signals the valve to open. It uses a solenoid. Electricity activates the solenoid coil. This moves the internal plunger. Gas can then flow out the nozzle.
How do I install this hanging type valve?
Mount it securely above the protected area. Use suitable brackets. Point the nozzle downward. Connect the inlet pipe to the FM200 supply. Connect the outlet pipe to the nozzle distribution network. Follow the system diagram exactly. Ensure electrical wires connect correctly to the 24V DC source.
Is this valve rated for FM200 systems?
Ee. It’s made specifically for FM200 extinguishing systems. The brass body handles the gas well. It works reliably under pressure. It meets required fire safety standards.
Does this valve need regular maintenance?
Ee. Inspect it visually every year. Check for damage or leaks. Test its operation during full system checks. Professionals should do this testing. They verify it opens fully when powered. They ensure it seals tight when closed. Replace it immediately if any problem is found.

(DC24V Solenoid Valve Hanging Ụdị FM200 Extinguisher Brass Nozzle Valve)
RỊỌRỌ OKWU
Ngwaahịa ndị metụtara

Manual Male Threads Ball Valve Plumbing Water Pipe Ball Valve With Long Handle

Pex X Pex Ball Valve dị elu 1/2″ Brass bọọlụ Valve

Quick Shipment 4 Inch NPT Thread 1/2″ Water Brass Gate Valve With Red Painted Drawn Iron Handwheel

Whole Brass Water Solenoid Valve 2W160-15 1/2” Normally Closed Brass Electric Magnetic Valve

SWD 1/2″ 3/4″ 1″ 1.25″1.5″ 2″ Nwanyị eriri Control Valve Maka Water Compact PVC Ball Valve na Handle

Eriri LPG Safety Valve REGO Pressure Relief Valves Cylinders 3127G 3129G Akwụkwọ ntuziaka General Brass Gas dị elu 10 PCS 1/4″
- Email: sales@pipesandfittings.net