Intelligent Heating Solutions Floor Heating Pipes
PRODUCT PARAMETERS
PIAV QHIA
Introduction of Floor Heating Pipes
Floor Heating Pipes(crosslinking polyethylene pipe) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Details of Floor Heating Pipes
we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:
Temperature tolerance: -70℃~110℃ working range
(instant temperature resistance up to 130℃)
Pressure performance: PN10 rated pressure 95℃ hot water long-term operation
Memory effect: Unique shape recovery features to avoid permanent creases
Corrosion resistance: Resistance to acid-base media (pH2-12) and microbial attack
Intergenerational evolution of product technology
| Nta | First generation PE-RT | Second generation PEX-B | Third generation PEX-A |
| Degree of crosslinking | no | 65-70% | ≥75% |
| Temperature rating | Class III | Level IV | Level V |
| Coefficient of thermal expansion | 0.18 mm/m ℃ | 0.15 mm/m ℃ | 0.12 mm/m ℃ |
| Burst pressure (95 ° C) | 5.2 MPa | 6.8 MPa | 8.4 MPa |
* Note: Data in this table are based on ISO15875 international standard test environment *
Specifications of Floor Heating Pipes
Standard pipe parameter matrix
| Specification and model | Outside diameter (mm) | Wall thickness (mm) | SDR value | Pressure rating | Length of applicable loop |
| e – 16 x 2.0 | 16 | 2.0 | 8.0 | S4 | ≤80m |
| e – 20 x 2.3 | 20 | 2.3 | 8.7 | S3.2 | ≤100m |
| PEX-25×2.8(enhanced) | 25 | 2.8 | 8.9 | S2.5 | ≤120m |
SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe
Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)
Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)
Analysis of multi-layer composite structure
Five-layer co-extrusion process:
1. Inner layer: PEX-A antibacterial layer (silver ion coating)
2. Bonding layer: modified polyethylene
3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)
4. Reinforcing layer: glass fiber reinforced PEX
5. Outer layer: anti-UV modified layer
Engineering grade product advantages
Laboratory verification data
Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)
Long-term hydrostatic strength: ≥50 years of life at 95℃/1.0MPa (ASTM F876)
Bending fatigue test: no crack at 10000 bending radius 5D cycles
Intelligent heating solution
mermaid
graph TD
A[heat source system] –> B[PEX diversity collector]
B –> C[PEX main pipe DN32]
C –> D[PEX floor heating coil DN16/20]
D –> E[Intelligent temperature control system]
E –> F[mobile APP remote management]
Applications of Floor Heating Pipes
Civil construction field
Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm
Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%
Commercial engineering cases
Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm
Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system
Special industrial applications
Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer
Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining
Global Certification System
Drinking water safety: NSF/ANSI 61, KTW (Germany)
Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Germany)
Environmental certification: Blue Angel (Blue Angel), LEED plus
Ntim thiab Xa Thauj
Nyob ntawm cov khoom thiab kom muaj nuj nqis,Peb tuaj yeem ua cov ntim ntawm coiled,yob,pob ntim,crates los yog thawv,etc..
Shipment:Los ntawm hiav txwv,los ntawm kev tsheb nqaj hlau,los ntawm huab cua los yog raws li cov neeg thov.
Company Profile
Luoyang Datang Energy Tech Co.Ltd was established in 2015 thiab nyob rau hauv High-tech txoj kev loj hlob cheeb tsam, Luoyang City, npog ib cheeb tsam loj nrog lub xeev-of-the-art chaw. Peb tsoom fwv muaj ib puag ncig txhawb nqa, suav nrog kev thauj mus los yooj yim thiab nkag mus rau cov khoom siv tseem ceeb. Txij li thaum pib hauv 2015, Peb tau cog lus rau kev ua tau zoo hauv cov yeeb nkab thiab fittings, txuas ntxiv kev tsim kho tshiab kom tau raws li kev ua lag luam xav tau.
If you need PPR Pipes and Fittings,Please feel free to contact us(sales@pipesandfittings.net)
Payment Terms
T/T,L/C at sight,Western Union & Paypal,etc..
FAQ of Floor Heating Pipes
Q: How to choose PEX pipe and aluminum-plastic pipe?
A: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).
Q: Floor heating pipe spacing design specification?
A: According to EN1264 standard:
Conventional area: 200mm spacing (pipe diameter 16mm)
Edge area: 150mm encryption area (extending 1.5m to external wall)
Bathroom: 175mm spacing + border insulation tape
THOV IB NQE LUS