Formulario di Kontakto

UL/FM Fire Alarm Check Valve | Kurpa di heru dúktil | Sistema di Spuitmentu di Kandela | DN50-DN300 | CE Sertifiká

PARAMETRONAN DI PRODUKTO

Material di kurpa Heru Dúktil (High-Strength)
Disc / Clapper Material Heru Dúktil / Staal Inoxidabel
Seal Material PTFE (Polytetrafluoroethylene) / EPDM / NBR
Valve Type Klep di kòntròl di alarma / Non-Return Valve
Rango di tamaño OEM Personalisa (Típiko: DN50 – DN300 / 2″ to 12″)
Nominal Pressure PN10 / PN16 (DEN 1902-2)
Temperature Range Haltu, Mediano, Abou, Ambient
Media Awa, Gas, Zeta, Acid, Base, and other fire extinguishing media
Deskripshon
PIDI UN SITA

Deskripshon

Bista General di Produkto

The UL/FM Fire Alarm Check Valve is a specialized fire protection valve designed for wet-pipe automatic sprinkler systems. Constructed from high-strength ductile iron, it offers exceptional corrosion resistance and a long service life in demanding fire protection environments. It is an ideal choice for commercial buildings, industrial facilities, high-rise apartments, warehouses, and other locations requiring reliable fire alarm capabilities and flow control.

UL/FM Fire Alarm Check Valve

Spesifikashonnan Tékniko

ParameterSpesifikashon
Nomber di Produkto Klep di kòntròl di alarma / Fire Alarm Check Valve
Tipo di konekshon Flanged (DEN 1092-2 PN10/PN16)
Operashon Automatic (Pressure Differential)
Structure Type Butterfly / Check / Gate / Relief (Customizable)
Revestimentu Revestimentu di Epoxy Pegá ku Fushon (RAL3000 Red / Blue)
Craft Casting
PersonalisashonOEM, ODM
SertifikashonUL Listá, FM Aprobá, CE Sertifiká
StandartDEN 1902-2 PN10/PN16, UL 312, FM 1630

Prinsipio di Trabou

The alarm check valve operates on a simple yet reliable pressure differential principle:

1. Standby State (System Pressurized): The system side of the valve is filled with pressurized water. The clapper remains closed due to its own weight and the pressure balance between the supply side and system side.

2. Fire Event (Sprinkler Activation): When a fire occurs and the sprinkler head opens, water pressure on the system side drops. The pressure differential opens the clapper, allowing water to flow from the supply side into the system piping.

3. Alarm Activation: Simultaneously, water enters the alarm port through a small orifice, flowing to the water motor gong (audible alarm) and pressure switch (electrical signal to the fire control panel). The bypass check valve prevents false alarms from pressure surges.

UL/FM Fire Alarm Check Valve

Karakterístika Klave

  1. High-Strength Ductile Iron Construction
  2. Integrated Alarm Activation – Dual Alarm Output
  3. UL, FM & CE Certified – Global Compliance
  4. Fusion-Bonded Epoxy Coating – Superior Corrosion Resistance
  5. Bypass Check Valve – False Alarm Prevention
  6. Wide Media Compatibility
  7. Flanged Connection – EN 1902-2 PN10/PN16

Aplikashonnan

  1. Automatic Fire Sprinkler Systems
  2. Fire Pump Discharge Lines
  3. Industrial Fire Protection
  4. High-Rise Building Risers
  5. Municipal Fire Protection Networks

UL/FM Fire Alarm Check Valve

Empaketamentu i Envio

Empaketahe ta dependé di e tipo i kantidat di produkto. Standard packing includes wooden cases with proper protection for flange faces and trim components. Envio por wòrdu areglá via laman, ferry, airu, òf segun petishon di kliente.

Kondishonnan di Pago

T/T, L/C na bista, Western Union & PayPal, etc.

Profil di e kompania

LUOYANG CAME ENERGY TECH CO., LTD ta un proveedó profeshonal di klep industrial, dediká na proveé ​​solushonnan di kontrol di fluho konfiabel pa protekshon kontra kandela, HVAC, tratamentu di awa, i sistemanan di tuberia industrial mundialmente. Tur produkto ta wòrdu fabriká segun normanan internashonal ku UL/FM, CE, i ISO 9001 sertifikashonnan. Ku riba 10 aña di eksperensia, un fasilidat moderno di 80,000 m2, i 200+ empleadonan profeshonal, nos ta sirbi klientenan den 10+ paisnan ku produktonan di kalidat, preis kompetitivo, i entrega konfiabel.

UL/FM Fire Alarm Check Valve

FAQ

Q1: What is the difference between an alarm check valve and a standard check valve?

UN: An alarm check valve is a specialized type of check valve; in addition to preventing backflow (like a standard check valve), it triggers an audible and visual alarm when water flows through the system. Standard check valves only prevent backflow and lack alarm functionality. Alarm check valves are primarily used in fire protection systems that require flow monitoring and alarm notification capabilities.

Q2: Which certification standards does this valve meet?

UN: This valve holds UL Listing (UL 312), FM Approval (FM 1630), and CE certification, meeting the strictest international safety and quality standards for fire protection equipment. These certifications ensure the product can be used in compliance with regulations for fire protection projects worldwide.

Q3: What is the function of the bypass check valve?

UN: The bypass check valve allows for slow, minor, and transient increases in supply pressure to pass through, thereby preventing false alarms caused by pressure fluctuations. It ensures that the alarm is triggered only when sprinkler heads actually activate and a sustained water flow occurs.

UL/FM Fire Alarm Check Valve

PIDI UN SITA

PIDI UN SITA