Formularz kontaktowy

Inteligentne rozwiązania grzewcze Rury do ogrzewania podłogowego

PARAMETRY PRODUKTU

Floor Heating Pipes(sieciująca rura z polietylenu) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Opis
Poproś o wycenę

Opis

Wprowadzenie Floor Heating Pips

Floor Heating Pipes(sieciująca rura z polietylenu) is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).

Details of Floor Heating Pipes

we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:

Temperature tolerance: -70℃~110℃ working range

(instant temperature resistance up to 130℃)

Pressure performance: PN10 rated pressure 95℃ hot water long-term operation

Memory effect: Unique shape recovery features to avoid permanent creases

Odporność na korozję: Resistance to acid-base media (pH2-12) and microbial attack

Intergenerational evolution of product technology

 Cechy First generation PE-RT Second generation PEX-B Third generation PEX-A
 Degree of crosslinking no 65-70%      ≥75%
 Temperature rating Class III Level IV Level V
 Coefficient of thermal expansion 0.18 mm/m ℃ 0.15 mm/m ℃ 0.12 mm/m ℃
 Burst pressure (95 ° C) 5.2 MPa 6.8 MPa 8.4 MPa

* Notatka: Data in this table are based on ISO15875 international standard test environment *

Specifications of Floor Heating Pips 

Standard pipe parameter matrix

Specification and modelŚrednica zewnętrzna (mm)Wall thickness (mm)Wartość SDRPressure ratingLength of applicable loop
PEX – 16 x 2.0162.08.0S4≤80m
PEX – 20 x 2.3202.38.7S3.2≤100m
PEX-25×2.8(enhanced)252.88.9S2.5≤120m

SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe

Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)

Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)

Analysis of multi-layer composite structure

Five-layer co-extrusion process:

1. Inner layer: PEX-A antibacterial layer (silver ion coating)

2. Bonding layer: modified polyethylene

3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)

4. Reinforcing layer: glass fiber reinforced PEX

5. Outer layer: anti-UV modified layer

mingineering grade product advantages

Laboratory verification data

Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)

Długotrwała wytrzymałość hydrostatyczna: ≥50 years of life at 95℃/1.0MPa (ASTM F876)

Bending fatigue test: no crack at 10000 bending radius 5D cycles

Intelligent heating solution

mermaid

graph TD

A[heat source system] –> B[PEX diversity collector]

B –> C[PEX main pipe DN32]

C –> D[PEX floor heating coil DN16/20]

D –> mi[Intelligent temperature control system]

mi –> F[mobile APP remote management]

Zastosowania Floor Heating Pips

Civil construction field

Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm

Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%

Commercial engineering cases

Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm

Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system

Special industrial applications

Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer

Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining

Global Certification System

Drinking water safety: NSF/ANSI 61, KTW (Germany)

Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Germany)

Environmental certification: Blue Angel (Blue Angel), LEED plus

Pakowanie i wysyłka

Zależy od produktów i ich ilości,moglibyśmy wykonać pakowanie zwijania,bułki,pakowanie pakietów,skrzynie lub pudełka,itp.

Wysyłka:Drogą morską,kolej żelazna,drogą powietrzną lub na życzenie klienta.

Profil firmy

Firma Luoyang Datang Energy Tech Co.Ltd została założona w 2015 i znajduje się w strefie rozwoju zaawansowanych technologii, Miasto Luoyang, obejmuje duży obszar z najnowocześniejszymi udogodnieniami. Nasz rząd oferuje wspierające środowisko, w tym wygodny transport i dostęp do niezbędnych zasobów. Od momentu powstania w 2015, dążymy do doskonałości w zakresie rur i złączek, ciągłe wprowadzanie innowacji, aby sprostać wymaganiom rynku.

Jeśli potrzebujesz rur i złączek PPR,Prosimy o kontakt nas(sales@pipesandfittings.net)

Warunki płatności

T/T,L/C w zasięgu wzroku,Western Union & PayPal,itp.

FAQ of Floor Heating Pips

Q: How to choose PEX pipe and aluminum-plastic pipe?

A: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).

Q: Floor heating pipe spacing design specification?

A: According to EN1264 standard:

Conventional area: 200mm spacing (pipe diameter 16mm)

Edge area: 150mm encryption area (extending 1.5m to external wall)

Bathroom: 175mm spacing + border insulation tape

ZAMÓW WYCENĘ

ZAMÓW WYCENĘ