Puka haapurororaa

AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

TE MAU PARAMETERS

Tuʻaroʻa
A TINIRAA I TE HOÊ PARAU

Tuʻaroʻa

Overview of AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

AC220V Brass 2/2 Way FX-04 ZG1/2Solenoid Valve is engineered for superior performance in plumbing, te fare hamaniraa tauihaa, e te mau faaohiparaa tapihooraa. Ua hamanihia mai roto mai i te lead-free, te parahi, E haapapû teie mau arapoa i te hoê vai maoro e te hoê faatereraa ti'aturihia no te taheraa o te pape, mǎhu, Mōno'i, e te tahi atu mau pape.

Na roto i te mau rave'a paturaa papû e te paturaa, E ohipa maitai ta tatou mau arapoa parahi, te taamuraa maitai roa, e te pato'iraa i te faaheporaa rahi—ma te faariro ia ratou ei vahi maitai roa no te faaearaa, ōfa'i, e te mau rave'a hamaniraa tauihaa.

Key Features of AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

Te paturaa brass moni rahi – Lead-free, te pato'i i te ino, e te maoro

Hoho'a Leak-Proof - Te mau tapa'o taa ê no te faatere i te pape

Te faaheporaa rahi & Te pato'iraa i te anuvera – Te ha'utiraa ti'aturihia i roto i te mau huru oraraa fifi

Te ohipa maitai - Te mau rave'a ohie no te taui i te mau tauiraa papû

Te mau faaohiparaa huru rau - E tu'ati i te pape, mǎhu, Mōno'i, e te mau faanahoraa HVAC

Rahi rau & Te mau maitiraa no te taairaa – I roto i te 1⁄4” ki te 2″ te mau rahi (NPT, Nga aho BSP)

 AC220V Brass 2/2 Way FX-04 ZG1/2

( AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid)

Specification of AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

Here’s the requirements for the AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid. This shutoff manages liquid or gas circulation. It uses electrical energy to open or shut. The valve operates 220 Volts Rotating Present (A/C). This voltage is common in lots of regions. The valve body is made from brass. Brass resists rust well. Brass manages lots of liquids safely. The valve type is 2/2 Way Normally Closed. It has 2 ports: inlet and electrical outlet. It has 2 states: open or shut. Typically shut indicates it turns off flow without power. Applying power opens up the flow path. The model designation is FX-04. This determines the details valve collection. The port connection uses ZG1/2threads. ZG is a parallel pipe thread requirement. Te 1/2 inch size fits typical piping. The shutoff requires a particular power degree. It consumes about 4.5 Watts when invigorated. This makes it power effective. The valve deals with various media. It handles air, vai, Mōno'i, and light gas. Check compatibility for certain chemicals. The shutoff endures pressure. Its maximum operating pressure is 1.0 MPa. This equals approximately 145 PSI. The shutoff takes care of a temperature range. It operates from -5 ° C e 80 ° C. This covers most common industrial usages. The seal product is usually NBR rubber. NBR supplies good oil resistance. The valve core utilizes magnetic stainless-steel. This makes certain trustworthy magnetic procedure. The shutoff fulfills necessary security requirements. It lugs CE qualification. Installment needs correct alignment. Mount it with the coil dealing with upwards. This stops particles buildup. Make sure the circulation direction matches the arrowhead. Connect cords properly. Use the consisted of terminals. Protect the coil from physical damage. Maintain the valve tidy. Stay clear of extreme dampness. This valve suits automation systems. It helps water control, air compressors, watering. It fits applications requiring on/off liquid control. The building and construction is durable. It supplies trustworthy life span. The layout is compact. This conserves space in your system. Maintenance demands are reduced.

 AC220V Brass 2/2 Way FX-04 ZG1/2

( AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid)

Applications of AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

This AC220V Brass 2/2 Way FX-04 ZG1/2Solenoid Shutoff manages automated on/off control for liquids or gases. It works dependably with many usual liquids. You discover it in various places needing fast, reputable circulation control.

One significant usage is controlling water flow. It functions well in water lines, filtering configurations, and loading stations. It transforms water circulation on or off promptly based upon an electric signal. This makes procedures efficient. You don’t require manual valves.

Industrial makers utilize this shutoff frequently. It manages coolant flow to devices, reducing liquids, or lubes. It makes certain devices get the right liquid at the right time. This shields equipment and keeps production smooth. It manages air flow in pneumatically-driven systems as well. This powers cyndrical tubes and actuators.

Cleansing systems require valves such as this. It regulates water or cleaning solutions in industrial washers, parts cleaners, and CIP systems. It provides exact timing for wash cycles. This saves water and chemicals. It cleans regular.

Irrigation systems take advantage of this shutoff. It controls water flow to various areas instantly. Timers or controllers inform it when to open or close. This saves labor and water. It guarantees plants obtain sprinkled appropriately.

This shutoff helps handle fuel circulation safely. It manages diesel, kerosene, or light oil in heaters or heating systems. Its brass body deals with these fuels well. It gives a reputable shut-off. This is important for safety and security.

Refine control applications utilize it. It handles the flow of chemicals, Sovents, or other process liquids. It responds quickly to regulate signals. This maintains the process stable. It stops spills or overflows.

Its brass building and construction makes it solid. Brass stands up to deterioration from water and lots of chemicals. The ZG1/2string prevails. This makes setup easy. The AC220V coil plugs into common power. This streamlines wiring. The FX-04 style is understood for integrity. It offers lengthy life span with very little maintenance. You need a valve that works every time. This gets the job done.

Te tapo'iraa e te tonoraa

Te faataa ra te reira i te mau tao'a e te qty,E nehenehe ta tatou e rave i te tapo'iraa o te coiling,rolls,Te tapo'iraa,Te mau afata e aore râ, te mau afata,e tē vai atura.

Te tonoraa:Na te moana,purumu,na roto i te manureva aore ra mai te aniraa a te taata hoo.

Hoho'a o te Taiete

Te mau haamaramaramaraa no ni'a i te mau haamaramaramaraa a Luoyang., Ltd. te hoê taata hamani tao'a tinito rahi roa'e o tei matau i te mau hu'ahu'a hu'ahu'a maitai roa e te mau tao'a. Ua ineine te reira e te mau reni hamaniraa tauihaa apî roa a'e e te turuhia ra e te hoê pŭpŭ 200 te feia toro'a, te horoa nei matou i te hoê reni tao'a rahi e hau atu i te 150 te mau huru paipa hu'ahu'a e te mau tauihaa i hamanihia no te horoa i te pape e te mau faanahoraa no te faataeraa i te pape, Te haaparareraa mǎhu, e te mau faanahoraa no te faahanahana i te tahua. I roto i ta tatou mau tao'a rahi, te vai ra te mau PVC Pipes e te mau tao'a, PE (HDPE) Te mau paipa e te mau tao'a, PPR Pipes me nga taputapu, e te mau paipa no te faahanahana i te tahua PEX.

E uiuiraa anei ta outou no ni'a i te HDPE Pipe, Eiaha e feaa faahou i te farerei ia matou!

Tel.:0086-183 3790 0677

Wechat: 0086-183 3790 0677

Whatsapp: 0086-183 3790 0677

Imera: mau hooraa@mau hooraa

Te mau parau aufau

T/T,L/C i te hi'oraa,Tooa o te râ & Paypal,e tē vai atura.

5 FAQs of AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid

What voltage does this solenoid valve need?
This valve runs on AC220V power. It won’t work with DC power sources. Ensure your power supply matches exactly. Using the wrong voltage damages the valve.

How do I install this brass solenoid valve?
Connect the ZG1/2female threads to your pipe. Make sure the arrow on the valve body points with the flow direction. Use thread seal tape properly. Avoid overtightening the connections. Check for leaks after installation.

What pressure can this valve handle?
It operates within 0 a 0.8 MPa water pressure. Exceeding 0.8 MPa causes damage. Pressure below 0 MPa might prevent proper closing. Always check your system pressure first.

Why might the valve leak when closed?
Dirt stuck inside the valve is the usual cause. Small particles block the seal from closing fully. Install a filter before the valve inlet. Clean the valve body if leaks happen. Damaged seals need replacement.

Does this valve need regular maintenance?
ae, inspect it periodically. Check for leaks around the body and connections. Listen for unusual buzzing sounds during operation. Clean the inlet filter regularly. Replace worn internal parts quickly. Proper maintenance extends its life.

 AC220V Brass 2/2 Way FX-04 ZG1/2

( AC220V Brass 2/2 Way FX-04 ZG1/2″ Auri solenoid)

A TINIRAA I TE HOÊ PARAU

A TINIRAA I TE HOÊ PARAU