Aloqa shakli

UL/FM Fire Alarm Check Valve | Egiluvchan temir tanasi | Yong'in sprinkler tizimi | DN50-DN300 | CE sertifikati

MAHSULOT PARAMETRLARI

Tana materiali Egiluvchan temir (High-Strength)
Disc / Clapper Material Egiluvchan temir / Zanglamaydigan po'lat
Seal Material PTFE (Polytetrafluoroethylene) / EPDM / NBR
Valf turi Signalni tekshirish valfi / Non-Return Valve
Hajmi diapazoni OEM Custom (Oddiy: DN50 – DN300 / 2″ to 12″)
Nominal bosim PN10 / PN16 (IN 1902-2)
Harorat diapazoni Yuqori, O'rta, Past, Ambient
OAV Suv, Gaz, Yog ', Acid, Base, and other fire extinguishing media
Tavsif
IQTISODIYoTI TALAB QILING

Tavsif

Mahsulotga umumiy nuqtai

The UL/FM Fire Alarm Check Valve is a specialized fire protection valve designed for wet-pipe automatic sprinkler systems. Constructed from high-strength ductile iron, it offers exceptional corrosion resistance and a long service life in demanding fire protection environments. It is an ideal choice for commercial buildings, industrial facilities, high-rise apartments, warehouses, and other locations requiring reliable fire alarm capabilities and flow control.

UL/FM Fire Alarm Check Valve

Texnik spetsifikatsiyalar

ParametrSpetsifikatsiya
Mahsulot nomi Signalni tekshirish valfi / Fire Alarm Check Valve
Ulanish turi Flanesli (IN 1092-2 PN10/PN16)
Operatsiya Automatic (Pressure Differential)
Structure Type Butterfly / Check / Darvoza / Relief (Moslashuvchan)
Qoplama Fusion-Bonded Epoxy Coating (RAL3000 Red / Moviy)
Craft Casting
MoslashtirishOEM, ODM
SertifikatlashUL Listed, FM Approved, CE sertifikati
StandartIN 1902-2 PN10/PN16, UL 312, FM 1630

Working Principle

The alarm check valve operates on a simple yet reliable pressure differential principle:

1. Standby State (System Pressurized): The system side of the valve is filled with pressurized water. The clapper remains closed due to its own weight and the pressure balance between the supply side and system side.

2. Fire Event (Sprinkler Activation): When a fire occurs and the sprinkler head opens, water pressure on the system side drops. The pressure differential opens the clapper, allowing water to flow from the supply side into the system piping.

3. Alarm Activation: Simultaneously, water enters the alarm port through a small orifice, flowing to the water motor gong (audible alarm) and pressure switch (electrical signal to the fire control panel). The bypass check valve prevents false alarms from pressure surges.

UL/FM Fire Alarm Check Valve

Asosiy xususiyatlar

  1. High-Strength Ductile Iron Construction
  2. Integrated Alarm Activation – Dual Alarm Output
  3. UL, FM & CE Certified – Global Compliance
  4. Fusion-Bonded Epoxy Coating – Superior Corrosion Resistance
  5. Bypass Check Valve – False Alarm Prevention
  6. Wide Media Compatibility
  7. Flanesli ulanish - EN 1902-2 PN10/PN16

Ilovalar

  1. Automatic Fire Sprinkler Systems
  2. Fire Pump Discharge Lines
  3. Industrial Fire Protection
  4. High-Rise Building Risers
  5. Municipal Fire Protection Networks

UL/FM Fire Alarm Check Valve

Qadoqlash va jo'natish

Qadoqlash mahsulot turiga va miqdoriga bog'liq. Standard packing includes wooden cases with proper protection for flange faces and trim components. Yuk tashish dengiz orqali amalga oshirilishi mumkin, temir yo'l, havo, yoki mijozning talabiga binoan.

To'lov shartlari

T/T, Ko'rinishda L/C, Western Union & PayPal, va hokazo.

Kompaniya profili

LUOYANG CAME ENERGY TECH CO., LTD professional sanoat vana yetkazib beruvchisi, yong'indan himoya qilish uchun ishonchli oqim nazorati echimlarini taqdim etishga bag'ishlangan, HVAC, suv bilan ishlov berish, va butun dunyo bo'ylab sanoat quvur tizimlari. Barcha mahsulotlar UL/FM bilan xalqaro standartlarga muvofiq ishlab chiqariladi, Idoralar, va ISO 9001 sertifikatlar. Bitta bilan 10 yillik tajriba, zamonaviy inshooti 80,000 m², va 200+ professional xodimlar, mijozlarga xizmat ko'rsatamiz 10+ sifatli mahsulotlarga ega mamlakatlar, raqobatbardosh narxlash, va ishonchli yetkazib berish.

UL/FM Fire Alarm Check Valve

TSS

1-savol: What is the difference between an alarm check valve and a standard check valve?

A: An alarm check valve is a specialized type of check valve; in addition to preventing backflow (like a standard check valve), it triggers an audible and visual alarm when water flows through the system. Standard check valves only prevent backflow and lack alarm functionality. Alarm check valves are primarily used in fire protection systems that require flow monitoring and alarm notification capabilities.

2-savol: Which certification standards does this valve meet?

A: This valve holds UL Listing (UL 312), FM Approval (FM 1630), and CE certification, meeting the strictest international safety and quality standards for fire protection equipment. These certifications ensure the product can be used in compliance with regulations for fire protection projects worldwide.

Q3: What is the function of the bypass check valve?

A: The bypass check valve allows for slow, minor, and transient increases in supply pressure to pass through, thereby preventing false alarms caused by pressure fluctuations. It ensures that the alarm is triggered only when sprinkler heads actually activate and a sustained water flow occurs.

UL/FM Fire Alarm Check Valve

IQTISODIYoTI TALAB QILING

IQTISODIYoTI TALAB QILING