LUOYANG HAERE ENERGY TECH CO.,LTD

SCH80 Kore-Metallic PVC Waea Hiko
NGA TAATA HUA
Whakaahuatanga
Whakataki o Pouaka Hiko PVC
PVC paipa (polyvinyl chloride pipe) is one of the most commonly used pipe materials in modern construction, ahumahi, me te hangarau o te taone. The two specifications, SCH40 and SCH80, are the most common types of applications. After rigorous testing and certification, they offer significant advantages in pressure resistance, parenga waikura, and ease of installation. Whether it is industrial, taone nui, water treatment, or drainage systems, SCH40 and SCH80 pipes offer superior performance and long life.
Nga korero mo Pouaka Hiko PVC
SCH40 Paipa PVC
High-quality materials: High-quality PVC raw materials are used to ensure the pipeline’s durability and ability to resist extreme temperatures (-15°C to 55°C; some products can reach 0°C to 60°C).
Multiple specifications: Available in a wide range of sizes from 1/2 “to 14” (or more significant) to meet different project needs.
Smooth inner wall: The smooth inner wall design reduces fluid resistance and improves flow efficiency while being less prone to scaling, making it easy to clean and maintain.
Te aukati waikura: Excellent chemical resistance, suitable for all kinds of corrosive media.
Simple construction: can use cold glue solution method, construction is fast and easy, and the joint is not easy to leak.
Electrical safety: Some products are UL and CSA certified, in line with the safety standards of electrical applications.
SCH80 PVC Pipe
High strength: The pipe wall is thicker, the pressure resistance is stronger, and it can withstand 3-4 times the rated pressure.
High pressure resistance: Suitable for high pressure fluid transmission system, to ensure the stability and safety of the system.
Ultraviolet resistance: Laid outdoors for a long time, life can reach more than 30 tau.
Chemical stability: Not easy to cause secondary pollution, suitable for drinking water system.
Versatility: Can be used for a variety of industrial applications, including electroplating, waste acid lye discharge, aquarium, etc.
Whakatakotoranga o Pouaka Hiko PVC
SCH40 & SCH80 PVC Pipe Dimensions and Tolerances
| Ahu (in inches) | Te diameter o waho (mm) | Tolerance (mm) | SCH40 wall thickness (mm) | Tolerance (mm) | SCH80 wall thickness (mm) | Tolerance (mm) |
| 1/2” | 21.34 | ±0.10 | 2.77 | +0.51 | 3.73 | +0.51 |
| 3/4” | 26.67 | ±0.10 | 2.87 | +0.51 | 3.91 | +0.51 |
| 1” | 33.40 | ±0.13 | 3.38 | +0.51 | 4.55 | +0.53 |
| 1¼” | 42.16 | ±0.13 | 3.56 | +0.51 | 4.85 | +0.58 |
| 1½” | 48.26 | ±0.15 | 3.68 | +0.51 | 5.08 | +0.61 |
| 2” | 60.32 | ±0.15 | 3.91 | +0.51 | 5.54 | +0.66 |
| 2½” | 73.02 | ±0.18 | 5.16 | +0.61 | 7.01 | +0.84 |
| 3” | 88.90 | ±0.20 | 5.49 | +0.66 | 7.62 | +0.91 |
| 4” | 114.30 | ±0.23 | 6.02 | +0.71 | 8.56 | +1.02 |
| 5” | 141.30 | ±0.25 | 6.55 | +0.79 | 9.52 | +1.14 |
| 6” | 168.28 | ±0.28 | 7.11 | +0.86 | 10.97 | +1.32 |
| 8” | 219.08 | ±0.38 | 8.18 | +0.99 | 12.70 | +1.52 |
| 10” | 273.50 | ±0.38 | 9.27 | +1.12 | 15.06 | +1.80 |
| 12” | 323.85 | ±0.38 | 10.31 | +1.24 | 17.45 | +2.08 |
| 14” | 355.60 | ±0.38 | 11.10 | +1.35 | 19.05 | +2.28 |
Operating temperature
PVC material: 0°C to 55°C (some products can reach 0°C to 60°C)
CPVC material: 0°C to 95°C
Nga tono o Pouaka Hiko PVC
Industrial Applications
Chemical plant: Used to transport corrosive media, such as acid lye, wastewater, etc.
Electroplating factory: as a transport pipeline of electroplating solution, to ensure the stability and safety of the plating process.
Oil and natural gas industry: used for oil field water injection, gas injection and oil and gas transmission system.
Municipal Applications
Water systems: Provide clean, safe drinking water to the city.
Pūnaha whakaheke wai: Ensure that the city drains smoothly to prevent disasters caused by stagnant water.
Sewage treatment: for the inlet and outlet water pipes and internal treatment processes of sewage treatment plants.
Building Applications
Waihanga wai: The drainage system used in the interior of a building, including toilets, kitchens, etc.
Electrical conduit: As a protective sleeve for electrical wires in the building to ensure the safe operation of electrical wires.
Heating and cooling system: Cold room piping for HVAC systems to increase energy efficiency and reduce operating costs.
Tarapu me te Tukunga
Depending on the products and qty, ka taea e tatou te hanga i te tarapi o te whiri, pukapuka, takai paihere, pouaka pouaka ranei, etc.
Tukunga: Ma te moana, tereina, by air, or at the customer’s request.
Kōtaha Kamupene
Luoyang Datang Energy Tech Co.Ltd i whakapumautia i roto i 2015 a kei roto i te rohe whakawhanaketanga hangarau teitei, Taone o Luoyang, kapi ana i tetahi waahi nui me nga taputapu hou. He taiao tautoko to tatou kawanatanga, tae atu ki te kawe waka me te whai waahi ki nga rauemi whakahirahira. Mai i te timatanga i roto i 2015, kua whakapau kaha matou ki te hiranga i roto i nga paipa me nga taputapu, auaha tonu ki te whakatutuki i nga hiahia o te maakete.
Mena ka hiahia koe ki nga Paipa PPR me nga taputapu,Tena koa whakapā mai tatou(sales@pipesandfittings.net)
Nga tikanga utu
T/T,L/C i te tirohanga,Western Union & Paypal,etc.
FAQ o Pouaka Hiko PVC
Q1.what are the main differences between SCH40 and SCH80?
The main difference between the SCH40 and the SCH80 is its wall thickness and its ability to withstand pressure. The SCH80 has thicker tube walls and is therefore able to withstand higher pressures, making it suitable for high-pressure fluid transfer systems. And the SCH40
Q2.why choose PVC pipe instead of pipe made of other materials?
PVC pipe has good corrosion resistance, UV resistance,
Q3: The difference with CPVC pipe?
Upper temperature limit: PVC 60℃ vs CPVC 93℃
Te ātete matū: CPVC has better resistance to aromatic hydrocarbons
Installation method: CPVC requires special adhesive
Q4: How to install in extreme weather?
Low temperature environment: use low temperature adhesive (construction temperature ≥-5℃)
High temperature area: Reserve 8-10mm expansion gap every 6 mita
Strong sunshine area: covered with aluminum foil sunscreen layer (reduce the coefficient of thermal expansion)
Q5: Service life guarantee?
10 years warranty (subject to the following conditions) :
Working pressure ≤ 80% of the rated value
Avoid direct UV rays (in unprotected condition)
Medium temperature fluctuation < ±15℃/h
Q6:What are the main application of sch40/sch80 PVC pipe?
SCH40 PVC Pipe:
Water supply systems: Suitable for residential, commercial and industrial water supply systems.
Pūnaha whakaheke wai: Used for internal building drainage, basement drainage and municipal drainage system.
Electrical application: As a conduit for electrical wires to protect cables from damage.
Cold room system: Suitable for HVAC systems due to its low heat conductivity, increasing cold room power and reducing insulation costs.
Other industrial applications: Such as chemical plants, electroplating plants, wastewater treatment plants, etc.
SCH8 PVC Pipe:
High-pressure fluid transmission: Such as oil field, chemical plant high-pressure fluid pipeline.
Water treatment system: The Pipes for soft water, pure water, deionized water and other systems.
Seawater transport: Suitable for seawater desalination, mariculture and other occasions.
Electrical protection: as a protective sleeve for high-voltage cables, to ensure the safe operation of the cables.
Other special applications: Such as underground irrigation systems, swimming pool water systems, etc.
TONO HE KORERO
HUA HUA

Rauemi Korehu Kirihou Te Diameter Nui PVC Paipa Wai Hose

Kounga Ahumahi Kirihou PVC Tube UPVC Pipe Mo te Wai Me Te Peehanga Nui

Ko nga Paipa PVC me nga taputapu mo te Punaha Whakainu Ahuwhenua Tiaki Wai

Pouaka PVC Cable Conduit Paipa Kowakawaka Polyvinyl Chloride Pipe

Heavy Duty PVC Rigid Conduit Pipe List

UPVC 4 Inihi 6 Inch CPVC Plastic HDPE PVC Water Pipe List
- Īmēra: sales@pipesandfittings.net
- WeChat: +86 18337900677








