LUOYANG DATANG ENERGY TECH CO.,LTD

DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
PRODUCT PARAMETERS
Description
Overview of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve is engineered for superior performance in plumbing, industrial, and commercial applications. Made from lead-free, corrosion-resistant brass, these valves ensure long-lasting durability and reliable flow control for water, gas, oil, and other fluids.
With precision machining and robust construction, our brass valves provide smooth operation, excellent sealing, and resistance to high pressure—making them ideal for residential, commercial, and industrial piping systems.
Key Features of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
Premium Brass Construction – Lead-free, corrosion-resistant, and durable
Leak-Proof Design – Tight seals for secure fluid control
High Pressure & Temperature Resistance – Reliable performance under demanding conditions
Smooth Operation – Easy-to-turn handles for precise flow adjustment
Versatile Applications – Compatible with water, gas, oil, and HVAC systems
Multiple Size & Connection Options – Available in ¼” to 2″ sizes (NPT, BSP threads)
(DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve)
Specification of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
This brass solenoid valve operates on 24V DC power. It’s the hanging kind made for straight placing onto FM200 fire reductions system cylinders. The shutoff body is solid brass for toughness and deterioration resistance. It regulates the circulation of FM200 snuffing out agent precisely. The nozzle shutoff ensures reputable discharge throughout a fire event.
Installment is simple making use of the hanging bracket. The valve connects directly to the cyndrical tube electrical outlet. This style saves area and simplifies system design. Standard NPT threads give secure pipe connections. The shutoff opens only when its 24V DC coil receives an electric signal. This coil is epoxy-sealed for defense against dampness and dust. The coil offers regular performance with time.
The valve handles details stress. Its maximum working stress is 360 PSI. Proof stress gets to 720 PSI. Burst stress is considerably greater for security. The shutoff runs effectively within a temperature level array. The most affordable temperature is -40 ° F. The greatest temperature is 165 ° F. The shutoff opening dimension is 0.75 inches. This orifice diameter regulates the FM200 flow price successfully. The shutoff body meets product standards for fire systems. The brass construction makes certain durability and leak-free procedure.
This element carries essential qualifications. It is FM Accepted. It is UL Listed. These authorizations validate the shutoff satisfies stringent safety and security and efficiency criteria. The shutoff is constructed for lengthy service life in demanding atmospheres. Its design reduces inner leakage. It gives a reputable shut-off when closed. This valve is a crucial part of automatic FM200 fire reductions systems. It makes certain the snuffing out representative launches just when required. Appropriate installation and upkeep are essential for ideal function. Constantly adhere to the producer’s directions and regional fire codes.
(DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve)
Applications of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
This brass nozzle valve regulates FM200 gas release in fire reductions systems. It installs suspending. This conserves area in limited setups. The valve uses a 24V DC solenoid. Low voltage operation improves safety. It avoids high voltage risks near delicate electronic devices.
FM200 snuffs out fires quick. It leaves no deposit. This shields useful tools. The shutoff deals with FM200 systems in essential areas. Web server areas require this defense. Information facilities count on it. Telecom centers use it too. Medical equipment spaces benefit. Industrial control panels need it. Tidy representative systems protect against damages from water or powder.
The hanging design streamlines installment expenses. It fits nicely above tools shelfs. Upkeep access stays clear. The brass body stands up to deterioration well. It manages FM200 gas accurately over time. The valve opens instantaneously when signified. This permits quick gas discharge. Quick discharge is vital for fire control.
The 24V DC signal originates from the fire panel. Electrical wiring is simple and risk-free. Electrical contractors mount it quickly. The shutoff integrates with typical discovery systems. It triggers upon verified fire signals. Reliability is vital forever security. This shutoff offers trustworthy performance. It satisfies strict fire safety requirements. Normal testing makes sure preparedness.
Packing and Shipment
Depends on the products and qty,we could make the packing of coiling,rolls,bundle packing,crates or boxes,etc.
Shipment:By sea,railway,by air or as customer’s request.
Company Profile
Luoyang Datang Energy Tech Co., Ltd. is a leading Chinese manufacturer specializing in high-quality plastic pipes and fittings. Equipped with state-of-the-art automated production lines and supported by a team of 200 professionals, we offer an extensive product line comprising over 150 types of plastic pipes and fittings designed for water supply and drainage systems, gas transmission, and floor heating systems. Our main products include PVC Pipes and Fittings, PE (HDPE) Pipes and Fittings, PPR Pipes and Fittings, and PEX Floor Heating Pipes.
Should you have any inquiries regarding HDPE Pipe Fitting, please do not hesitate to contact us!
Tel.:0086-183 3790 0677
Wechat: 0086-183 3790 0677
Whatsapp: 0086-183 3790 0677
Email: sales@pipesandfittings.net
Payment Terms
T/T,L/C at sight,Western Union & Paypal,etc.
5 FAQs of DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve
What does this brass nozzle valve do?
It controls FM200 fire suppressant flow. The valve stays closed normally. It opens when the system needs to discharge gas. This stops fires fast.
Why does it need 24V DC power?
24V DC is standard for fire systems. It’s safe. It’s reliable. The power signals the valve to open. It uses a solenoid. Electricity activates the solenoid coil. This moves the internal plunger. Gas can then flow out the nozzle.
How do I install this hanging type valve?
Mount it securely above the protected area. Use suitable brackets. Point the nozzle downward. Connect the inlet pipe to the FM200 supply. Connect the outlet pipe to the nozzle distribution network. Follow the system diagram exactly. Ensure electrical wires connect correctly to the 24V DC source.
Is this valve rated for FM200 systems?
Yes. It’s made specifically for FM200 extinguishing systems. The brass body handles the gas well. It works reliably under pressure. It meets required fire safety standards.
Does this valve need regular maintenance?
Yes. Inspect it visually every year. Check for damage or leaks. Test its operation during full system checks. Professionals should do this testing. They verify it opens fully when powered. They ensure it seals tight when closed. Replace it immediately if any problem is found.
(DC24V Solenoid Valve Hanging Type FM200 Extinguisher Brass Nozzle Valve)
REQUEST A QUOTE
RELATED PRODUCTS

OEM Small Square Brass Angle Valve for Bathroom & Kitchen Manual Water Oil Gas Control Ball Structure

Hospital Alarm System Gas Isolation Valve Copper Pipes With Brass Gas Line Ball Valve

Normally Closed 3/4 Inch 1/2 Inch 12 Volt 24 Volt Water Electric Solenoid Valve

High Quality Manual Full Brass Gate Valve for General Water Plumbing Work Customizable OEM Support

Yuson 3375-10 Single Handle 2 Way Diverter Bathroom Hot and Cold Water Mixer Valve Brass Shower Faucet

Stable Supply of 304 Stainless Steel Material Ball Valve High Pressure Resistant Long Handle Short Handle Switch Ball Valve
-
Email: sales@pipesandfittings.net
-
WeChat: +86 18337900677