LUOYANG DATANG ENERGY TECH CO.,LTD

LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
PRODUCT PARAMETERS
Description
Overview of LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer is essential components in gas supply systems, used to control the flow and pressure of gas in pipelines. They play a critical role in ensuring safety, efficiency, and reliability in residential, commercial, and industrial applications. Whether for natural gas, propane, or other gaseous fuels, our high-quality gas valves offer precise regulation and durable performance under varying conditions.
Features of LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
High durability and corrosion resistance materials
Precision engineering for accurate gas flow control
Safe and leak-proof design for reliable operation
Easy installation and maintenance
Available in various sizes and types to suit different applications
(LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer)
Specifications of LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
This gas control shutoff takes care of gas circulation for LPG or natural gas home appliances. It is made from solid brass. Brass withstands corrosion well. This shutoff lasts a long time. It regulates gas going to your stove burner or fryer precisely. You turn the knob to change the flame. You obtain the warmth degree you need.
A vital feature is the flameout security gadget. This is an important safety part. It automatically shuts off gas if the fire goes out unexpectedly. A gust of wind could blow it out. Boiling fluid may spill over and extinguish it. The safety and security probe detects the flame warm. The probe links to the shutoff. If the fire vanishes, the probe cools off quickly. This air conditioning causes the valve. The shutoff breaks closed instantaneously. Gas flow stops totally. This avoids hazardous gas leaks. Gas build-up is a significant fire or explosion threat. This safety and security feature provides essential peace of mind.
The shutoff body utilizes resilient brass building. Brass handles high temperatures accurately. It stands up to the continuous heat near burners. Links are common dimensions. Installation is straightforward for specialists. This valve fits most common gas ovens. It works with tabletop heaters. It works with business fryers also. Dependable gas control is important for secure food preparation. This valve provides constant efficiency. It ensures your device runs securely day after day. Appropriate installment by a qualified expert is obligatory for security. Constantly adhere to local gas codes and regulations.
(LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer)
Applications of LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
This LPG NG copper valve controls gas flow to oven burners or fryers. It takes care of gas shipment precisely. You get constant flame stamina for cooking. This matters for temperature control. The shutoff body utilizes durable copper. Copper stands up to rust well. It deals with warmth efficiently. This valve lasts longer under day-to-day usage.
Security is vital with gas devices. This shutoff consists of a vital flameout defense gadget. It uses a thermocouple sensor. The sensing unit discovers the heater flame. If the flame goes out unexpectedly, the sensing unit responds quickly. It cuts the gas supply instantaneously. This stops dangerous gas leakages. Gas accumulation creates fire or surge risks. This safety attribute protects your cooking area.
The shutoff deals with both LPG and gas. You pick the ideal model for your fuel type. Installment is uncomplicated. It fits basic gas line links. Upkeep is straightforward. Just look for leaks occasionally. Clean the outside when required.
Trustworthy performance is essential. This shutoff guarantees smooth gas circulation. It avoids aggravating stress drops. Your heaters light quickly whenever. Constant warm improves cooking outcomes. Business fryers require steady fuel supply. This shutoff supplies that accurately. Home stoves benefit as well. It uses satisfaction with integrated safety and security.
Packing and Shipment
Depends on the products and qty,we could make the packing of coiling,rolls,bundle packing,crates or boxes,etc.
Shipment:By sea,railway,by air or as customer’s request.
Company Profile
Luoyang Datang Energy Tech Co., Ltd. is a leading Chinese manufacturer specializing in high-quality plastic pipes and fittings. Equipped with state-of-the-art automated production lines and supported by a team of 200 professionals, we offer an extensive product line comprising over 150 types of plastic pipes and fittings designed for water supply and drainage systems, gas transmission, and floor heating systems. Our main products include PVC Pipes and Fittings, PE (HDPE) Pipes and Fittings, PPR Pipes and Fittings, and PEX Floor Heating Pipes.
Should you have any inquiries regarding HDPE Pipe Fitting, please do not hesitate to contact us!
Tel.:0086-183 3790 0677
Wechat: 0086-183 3790 0677
Whatsapp: 0086-183 3790 0677
Email: sales@pipesandfittings.net
Payment Terms
T/T,L/C at sight,Western Union & Paypal,etc.
5 FAQs of LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer
What is this valve for?
This valve controls gas flow to stoves, burners, or fryers. It connects between your gas source and the appliance. It manages the gas supply safely. It uses copper for durability against gas corrosion. It works with both LPG and natural gas systems.
How does the flameout protection work?
The valve has a thermocouple near the flame. Heat from the flame creates a small electric current. This current keeps an internal solenoid open. This allows gas to flow. If the flame goes out unexpectedly, the thermocouple cools. The current stops. The solenoid closes instantly. This cuts the gas supply. This prevents dangerous gas leaks.
Can I use this valve with my existing stove?
Check your stove’s connection type and size first. This valve has standard threaded fittings. Measure your current gas line connections. Compare them to the valve specifications. Ensure the valve matches your fuel type. LPG and NG require different pressure settings sometimes. Confirm the valve setting matches your gas supply pressure.
Is professional installation needed?
Yes. Gas connections are dangerous if done wrong. Always hire a licensed gas fitter. They ensure the valve is installed correctly. They check for leaks. They verify the flameout protection activates properly. DIY installation risks gas leaks, fire, or explosion. Safety requires expert installation and testing.
Why won’t my stove stay lit after installing this?
Several things could cause this. First, check the thermocouple position. It must sit directly in the burner flame. If it’s misaligned, it won’t detect heat. Second, ensure all connections are tight. Gas leaks affect pressure. Third, inspect the thermocouple for damage. A bent or dirty sensor won’t work right. Fourth, confirm the valve is set for your specific gas type. Wrong settings prevent proper operation.
(LPG NG Copper Valve Gas Control Valve Gas Safety Valve With Flameout Protection Device for Gas Stove Burner Fryer)
REQUEST A QUOTE
RELATED PRODUCTS
1/4 Inch Fuel Gas Pressure Reducing Regulator Valve NPT Standard Used in Boiler burner Combustion Systems in Ho Chi Minh/Sumatra
2-piece Medical Brass Gas Ball Valve Isolation Shut-off Ball Valve With Extensions Oxygen Cleaned Lockable Line Pipeline Valve
Factory Direct Supply Zinc/Aluminum Gas Valve for Home Cooking Gas Use – Mainly for Bolivia Market
Threaded LPG Safety Valve Pressure Relief Valves Cylinders 3127G 3129G High Quality Brass Gas General Manual 10 PCS 1/4″
2 Way Normally Open Miniature Compact Water Air Gas Steam Brass Solenoid Valve 1/8” 1/4” 12VDC 24VDC 24VAC 110VAC 220VAC
Manual Brass Ball Valves For Water Gas Oil Ball Valve 2 Inch
-
Email: sales@pipesandfittings.net
-
WeChat: +86 18337900677