Formular de contact

Conductă de încălzire prin pardoseală PEX rezistentă la temperaturi ridicate

PARAMETRII PRODUSULUI

PEX High Temperature Resistant Floor Heating Pipe is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Descriere
CERERE O CITATE

Descriere

Introducere a PEX Floor Heating Pipe

Conductă de încălzire prin pardoseală PEX rezistentă la temperaturi ridicate is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).

Details of PEX Floor Heating Pipe

we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:

  • Temperature tolerance: -70℃~110℃ working range (instant temperature resistance up to 130℃)
  • Pressure performance: PN10 rated pressure 95℃ hot water long-term operation
  • Memory effect: Unique shape recovery features to avoid permanent creases
  • Rezistenta la coroziune: Resistance to acid-base media (pH2-12) and microbial attack

Intergenerational evolution of product technology

 Caracteristici First generation PE-RT Second generation PEX-B Third generation PEX-A
 Degree of crosslinking no 65-70%      ≥75%
 Evaluarea temperaturii Class III Level IV Level V
 Coefficient of thermal expansion 0.18 mm/m ℃ 0.15 mm/m ℃ 0.12 mm/m ℃
 Burst pressure (95 °C) 5.2 MPa 6.8 MPa 8.4 MPa

* Nota: Data in this table are based on ISO15875 international standard test environment *

Specificatiile de PEX Floor Heating Pipe 

Standard pipe parameter matrix

Specification and modelDiametrul exterior (mm)Grosimea peretelui (mm)Valoarea DSTPresiune nominalăLength of applicable loop
PEX – 16 x 2.0162.08.0S4≤80m
PEX – 20 x 2.3202.38.7S3.2≤100m
PEX-25×2.8(enhanced)252.88.9S2.5≤120m

SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe

Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)

Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)

Analysis of multi-layer composite structure

Five-layer co-extrusion process:

  • 1. Stratul interior: PEX-A antibacterial layer (silver ion coating)
  • 2. Bonding layer: modified polyethylene
  • 3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)
  • 4. Reinforcing layer: glass fiber reinforced PEX
  • 5. Outer layer: anti-UV modified layer

Engineering grade product advantages

Laboratory verification data

  • Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)
  • Rezistență hidrostatică pe termen lung: ≥50 years of life at 95℃/1.0MPa (ASTM F876)
  • Bending fatigue test: no crack at 10000 bending radius 5D cycles

Intelligent heating solution

mermaid

graph TD

  • O [heat source system] –> B [PEX diversity collector]
  • B –> C [PEX main pipe DN32]
  • C –> D [PEX floor heating coil DN16/20]
  • D –> E [Sistem inteligent de control al temperaturii]
  • E –> F [mobile APP remote management]

Aplicatii ale PEX Floor Heating Pipe

Civil construction field
  • Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm
  • Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, eficienta constructiei a crescut cu 40%
Commercial engineering cases
  • Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm
  • Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system
Aplicații industriale speciale
  • Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer
  • Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining
Global Certification System
  • Drinking water safety: NSF/ANSI 61, KTW (Germania)
  • Fire safety certification: BS476 Part6/7 (Regatul Unit), DIN4102 B1 (Germania)
  • Environmental certification: Blue Angel (Blue Angel), LEED plus

Ambalare și expediere

Depinde de produse și de cantitate,am putea face ambalarea bobinei,rulouri,ambalare pachet,lăzi sau cutii,etc.

Expediere:Pe mare,feroviar,pe calea aerului sau la cererea clientului.

Profilul Companiei

Luoyang Datang Energy Tech Co.Ltd a fost stabilit în 2015 și situat în zona de dezvoltare high-tech, Orașul Luoyang, acoperă o suprafață mare cu facilități de ultimă generație. Guvernul nostru oferă un mediu de sprijin, inclusiv transport convenabil și acces la resursele esențiale. De la începuturi în 2015, ne-am dedicat excelenței în țevi și fitinguri, inovând continuu pentru a satisface cerințele pieței.

Condiții de plată

T/T,L/C la vedere,Western Union & Paypal,etc.

FAQ of PEX Floor Heating Pipe

Î1: How to choose PEX pipe and aluminum-plastic pipe?

O: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).

Q2: Floor heating pipe spacing design specification?

O: According to EN1264 standard:

Conventional area: 200mm spacing (pipe diameter 16mm)

Edge area: 150mm encryption area (extending 1.5m to external wall)

Baie: 175mm spacing + border insulation tape

CERERE O CITATE

CERERE O CITATE