LUOYANG CAME ENERGY TECH CO., LTD

Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
PARAMETRI IZDELKA
Opis
Overview of Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use is engineered for superior performance in plumbing, industrijski, in komercialne aplikacije. Izdelano iz brez svinca, korozijsko odporna medenina, ti ventili zagotavljajo dolgotrajno vzdržljivost in zanesljiv nadzor pretoka vode, plin, olje, in druge tekočine.
Z natančno obdelavo in robustno konstrukcijo, naši medeninasti ventili zagotavljajo nemoteno delovanje, odlično tesnjenje, in odpornost na visok pritisk, zaradi česar so idealni za stanovanja, komercialni, in industrijski cevni sistemi.
Key Features of Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
Vrhunska konstrukcija iz medenine – brez svinca, odporen proti koroziji, in trpežna
Zasnova, odporna na puščanje – Tesna tesnila za varen nadzor tekočine
Visok pritisk & Temperaturna odpornost – Zanesljivo delovanje v zahtevnih pogojih
Gladko delovanje – Ročaji, ki jih je enostavno vrteti za natančno nastavitev pretoka
Vsestranske uporabe – združljivo z vodo, plin, olje, in sistemi HVAC
Več velikosti & Možnosti povezave – na voljo v ¼” do 2″ velikosti (NPT, BSP niti)

(Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use)
Specification of Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
This brass gas safety and security shutoff quits gas leaks instantly. It has fire failure protection. A constant pilot light checks the main heater fire. The pilot burner goes out if the primary fire fails suddenly. The valve shuts off the gas supply instantly. This avoids harmful gas buildup. It shields cooking areas from fire or explosion threats.
Use this shutoff in Western cooking areas needing high security. It functions well in busy hotel kitchens. It fits perfectly in house gas cooktops also. The shutoff takes care of typical natural gas or LPG. It links easily to conventional gas lines. Usual link sizes are 1/2 inch oz 3/4 inch NPT threads. Other sizes are offered.
The strong brass body makes certain long life. Brass stands up to rust from gas and dampness. It stands up to heats near cooking home appliances. The valve runs accurately under typical gas stress. Common working stress depends on 0.5 bar or 7.25 PSI. Inspect specific stress ratings for your model. The valve operates in warm settings. Optimum ambient temperature level is typically 60 ° C (140 ° F).
Installation is uncomplicated for qualified specialists. Follow neighborhood gas codes precisely. Make sure correct air flow exists. The constant pilot system supplies consistent monitoring. It reacts faster than periodic pilot systems. This shutoff fulfills rigorous international safety standards. Look for CE, UL, or CSA marks. These certifications ensure efficiency and safety. Normal upkeep checks are straightforward. Maintain the pilot orifice clean. Guarantee the thermocouple detects heat properly. This valve offers peace of mind. It prevents crashes properly. Trusted security is important for any type of gas device.

(Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use)
Applications of Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
This brass gas security shutoff maintains people secure in kitchens. It utilizes flame failing security with a continuous pilot. This system quits gas leaks instantly if the fire goes out. This protects against dangerous gas accumulation. Crashes happen less. Comfort increases.
The shutoff body is solid brass. Brass manages challenging cooking area conditions well. It withstands rust from warm, mokrota, and cleansing chemicals. The valve will not jam or rust easily. You obtain long-lasting, trustworthy operation. It works completely for busy Western kitchen areas. Hotels need trustworthy equipment. This shutoff supplies. Home kitchen areas benefit as well. Safety is essential almost everywhere gas cooks food.
Right here’s just how the safety feature functions. A small pilot flame burns constantly near the major heater. A thermocouple sensor rests right in this pilot flame. The thermocouple senses the warmth. It creates a small electric existing. This present holds the gas shutoff open. The primary gas flows to the burner. The flame stays lit.
Something unforeseen takes place. An abrupt draft blows out the fire. Someone spills liquid putting out the fire. The pilot flame dies. The thermocouple cools down quick. It quits making the electrical existing. The safety and security valve responds immediately. It turns off the gas supply entirely. No gas keeps dripping out. This protects against possible explosions or poisoning. People remain risk-free. Home remains secured.
Procedure is straightforward. Turn the hand-operated handle to begin gas flow. Light the pilot flame initially. Hold the knob for a couple of secs. This warms the thermocouple. Then launch the knob. The pilot stays lit. Currently transform the handle further. This lights the main burner. Adjust the fire height as needed. Cooking begins. Transform the handle back to off when ended up. The gas stops. The pilot goes out. The shutoff resets itself for next time.
This valve fits many appliances needing risk-free gas control. Utilize it in business frying pans. Utilize it in sturdy fryers. Use it in dining establishment cooktops and stoves. Hotels mount them in banquet kitchen tools. Home cooks placed them in gas ranges. Anywhere open flame food preparation utilizes gas, this shutoff adds crucial security. It takes care of everyday food preparation needs reliably.
Pakiranje in pošiljanje
Odvisno od izdelkov in količine,lahko naredimo pakiranje zvijanja,zvitki,paketno pakiranje,zabojih ali škatlah,itd.
Pošiljka:Po morju,železnica,po zraku ali po želji stranke.
Profil podjetja
Luoyang Datang Energy Tech Co., doo. je vodilni kitajski proizvajalec, specializiran za visokokakovostne plastične cevi in fitinge. Opremljen z najsodobnejšimi avtomatiziranimi proizvodnimi linijami in s podporo ekipe 200 strokovnjaki, nudimo obsežno linijo izdelkov, ki obsega več kot 150 vrste plastičnih cevi in fitingov za sisteme oskrbe z vodo in odvodnjavanja, prenos plina, in sistemi talnega ogrevanja. Naši glavni proizvodi vključujejo PVC cevi in fitinge, PE (HDPE) Cevi in fitingi, PPR cevi in fitingi, in PEX cevi za talno ogrevanje.
Če imate kakršna koli vprašanja v zvezi s priključkom za cevi HDPE, prosimo, ne oklevajte in nas kontaktirajte!
Tel.:0086-183 3790 0677
Wechat: 0086-183 3790 0677
WhatsApp: 0086-183 3790 0677
E-pošta: sales@pipesandfittings.net
Plačilni pogoji
T/T,L/C na vpogled,Western Union & Paypal,itd.
5 FAQs of Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use
Tukaj so 5 FAQs about the Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot:
What does this gas safety valve do?
This valve controls gas flow to appliances like ovens or heaters. Its key feature is automatic shutdown. If the main flame goes out unexpectedly, the valve cuts the gas supply fast. This prevents dangerous gas leaks. It uses a continuous pilot light for this protection.
Why does the pilot light stay on all the time?
The pilot light is essential. It acts like a sensor. The pilot flame heats a special part inside the valve (a thermocouple or thermopile). This heat creates a small electrical signal. The signal tells the valve it’s safe to stay open. If the pilot light fails, the signal stops. The valve shuts immediately.
How does it stop gas if the main flame dies?
The main burner flame relies on the pilot. If the main flame blows out, the pilot light usually stays lit. The valve remains open. But if both flames go out, the heat-sensing part cools down. The electrical signal vanishes. This triggers an internal mechanism. The mechanism snaps the gas valve closed. Gas flow stops completely.
Kaj počne “Continuous Pilot” pomeniti?
“Continuous Pilot” means the small pilot flame burns non-stop during appliance operation. You don’t need to relight it each time you turn the main burner on or off. The pilot provides constant monitoring. It ensures immediate safety shutdown if needed. It also allows instant main burner ignition whenever you want heat.
Kje se ta ventil običajno uporablja?
This valve suits places needing reliable, automatic gas safety. It’s common in Western kitchens for ranges and ovens. Hotels use it for commercial cooking equipment and large water heaters. Households install it on gas heaters, boilers, and some cooktops. Any gas appliance needing flame failure protection benefits from this valve.

(Brass Gas Safety Valve with Flame Failure Protection – Continuous Pilot for Western Kitchen, Hotel & Household Use)
ZAHTEVAJTE PONUDBO
PORODNI IZDELKI

Ročaj iz nerjavečega jekla Kroglični ventil iz medenine, Primerno za visokotemperaturno industrijo, Primerno za Steam,OMG kislina, Priročnik

Ball Valve Two Way Ball Valve Stainless Steel 1000WOG 2000WOG Ball Valve

Univerzalni 4-točkovni 3/2-točkovni ventil Dodatki za čistilec vode Priključek za pipo Ročno stikalo Tripotni krogelni ventil za avto

Medeninasti enosmerni povratni ventil polne velikosti Medeninasti povratni ventili za izvirsko vodo 1/2”-2” Medeninasti kontrolni ventil

Neposredno- Medeninasti vodni krogelni ventil z zunanjim navojem iz medeninastega krogelnega ventila polne velikosti

Varnostna naprava za kuhinjski plinski štedilnik Direct s Plinski elektromagnetni ventil
- E-pošta: sales@pipesandfittings.net
- WeChat: +86 18337900677