Contact Form

PEX High Temperature Resistant Floor Heating Pipe

MGA PARAMETER NG PRODUKTO

PEX High Temperature Resistant Floor Heating Pipe is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).
Paglalarawan
Humiling ng Quote

Paglalarawan

Introduction of PEX Floor Heating Pipe

PEX High Temperature Resistant Floor Heating Pipe is one of the most important material innovations in the field of HVAC in the 21st century. Through the high energy electron irradiation crosslinking process (PEX-A) or silane hydrolytic crosslinking technology (PEX-B).

Details of PEX Floor Heating Pipe

we transform the ordinary polyethylene molecular structure into a three-dimensional network crosslinking system to achieve:

Temperature tolerance: -70℃~110℃ working range

(instant temperature resistance up to 130℃)

Pressure performance: PN10 rated pressure 95℃ hot water long-term operation

Memory effect: Unique shape recovery features to avoid permanent creases

Corrosion resistance: Resistance to acid-base media (pH2-12) and microbial attack

Intergenerational evolution of product technology

 Features First generation PE-RT Second generation PEX-B Third generation PEX-A
 Degree of crosslinking no 65-70%      ≥75%
 Temperature rating Class III Level IV Level V
 Coefficient of thermal expansion 0.18 mm/m ℃ 0.15 mm/m ℃ 0.12 mm/m ℃
 Burst pressure (95 ° C) 5.2 MPa 6.8 MPa 8.4 MPa

* Note: Data in this table are based on ISO15875 international standard test environment *

Specifications of PEX Floor Heating Pipe 

Standard pipe parameter matrix

Specification and modelOutside diameter (mm)Wall thickness (mm)SDR valuePressure ratingLength of applicable loop
PEX – 16 x 2.0162.08.0S4≤80m
PEX – 20 x 2.3202.38.7S3.2≤100m
PEX-25×2.8(enhanced)252.88.9S2.5≤120m

SDR (Standard dimension ratio) : The ratio of outer diameter to wall thickness determines the balance of rigidity and flexibility of the pipe

Oxygen permeability: EVOH oxygen blocking layer ≤0.1g/m³·day (DIN4726 standard)

Thermal conductivity: 0.38W/(m·K) (30% better than copper pipe)

Analysis of multi-layer composite structure

Five-layer co-extrusion process:

1. Inner layer: PEX-A antibacterial layer (silver ion coating)

2. Bonding layer: modified polyethylene

3. Oxygen blocking layer: EVOH (ethylene-vinyl alcohol copolymer)

4. Reinforcing layer: glass fiber reinforced PEX

5. Outer layer: anti-UV modified layer

Engineering grade product advantages

Laboratory verification data

Cyclic pressure test: 5000 1.0MPa pressure fluctuations (ENISO10508)

Long-term hydrostatic strength: ≥50 years of life at 95℃/1.0MPa (ASTM F876)

Bending fatigue test: no crack at 10000 bending radius 5D cycles

Intelligent heating solution

mermaid

graph TD

A[heat source system] –> B[PEX diversity collector]

B –> C[PEX main pipe DN32]

C –> D[PEX floor heating coil DN16/20]

D –> E[Intelligent temperature control system]

E –> F[mobile APP remote management]

Applications of PEX Floor Heating Pipe

Civil construction field

Villa floor heating system: It is recommended to use PEX-20×2.3 pipe with a double zigzag cloth pipe with a spacing of 150mm

Apartment hardcover room: PEX-16×2.0 pipe + modular quick assembly system, construction efficiency increased by 40%

Commercial engineering cases

Snow melting system of ice and snow venue: stable operation in -25℃ environment, tube spacing encrypted to 100mm

Agricultural greenhouse heating: pesticide corrosion resistant design, with PE-RT mixed transport system

Special industrial applications

Hangar deicing system: anti-static PEX tube + carbon fiber reinforced layer

Chemical pipeline heat tracing: three-layer oxygen blocking structure +PTFE lining

Global Certification System

Drinking water safety: NSF/ANSI 61, KTW (Germany)

Fire safety certification: BS476 Part6/7 (UK), DIN4102 B1 (Germany)

Environmental certification: Blue Angel (Blue Angel), LEED plus

Pag-iimpake at Pagpapadala

Depende sa mga produkto at dami,maaari naming gawin ang pag-iimpake ng likid,mga rolyo,bundle packing,crates o kahon,atbp.

Pagpapadala:Sa pamamagitan ng dagat,riles,sa pamamagitan ng hangin o bilang kahilingan ng customer.

Profile ng Kumpanya

Ang Luoyang Datang Energy Tech Co.Ltd ay itinatag noong 2015 at matatagpuan sa High-tech na development zone, Luoyang City, sumasaklaw sa isang malaking lugar na may mga makabagong pasilidad. Nag-aalok ang ating pamahalaan ng isang matulunging kapaligiran, kabilang ang maginhawang transportasyon at access sa mahahalagang mapagkukunan. Mula nang magsimula noong 2015, kami ay nakatuon sa kahusayan sa mga tubo at kasangkapan, patuloy na nagbabago upang matugunan ang mga pangangailangan sa merkado.

Kung kailangan mo ng PPR Pipe and Fittings,Please feel free to contact us(sales@pipesandfittings.net)

Mga Tuntunin sa Pagbabayad

T/T,L/C sa paningin,Western Union & Paypal,atbp.

FAQ of PEX Floor Heating Pipe

Q: How to choose PEX pipe and aluminum-plastic pipe?

A: In the field of radiant heating, all-plastic PEX tubes have better heat transfer efficiency (thermal conductivity 0.38 vs 0.45 W/mK) and lower linear expansion rate (0.035% vs 0.025%/℃).

Q: Floor heating pipe spacing design specification?

A: According to EN1264 standard:

Conventional area: 200mm spacing (pipe diameter 16mm)

Edge area: 150mm encryption area (extending 1.5m to external wall)

Bathroom: 175mm spacing + border insulation tape

HUMILING NG QUOTE