PRODUCT PARAMETERS

Body Material Duktiel izer (High-Strength)
Skiif / Clapper Material Duktiel izer / Rustfrij stiel
Seal materiaal PTFE (Polytetrafluoroethylene) / EPDM / NBR
Valve Type Alarm Check Valve / Non-Return Valve
Grutte Range OEM Oanpaste (Typysk: DN50 – DN300 / 2″ to 12″)
Nominale druk PN10 / PN16 (YN 1902-2)
Temperatuer Range Heech, Medium, Leech, Ambient
Media Wetter, Gas, Oalje, Acid, Base, and other fire extinguishing media
Beskriuwing
FERGESE IN SITAATJE

Beskriuwing

Produkt Oersjoch

The UL/FM Fire Alarm Check Valve is a specialized fire protection valve designed for wet-pipe automatic sprinkler systems. Constructed from high-strength ductile iron, it offers exceptional corrosion resistance and a long service life in demanding fire protection environments. It is an ideal choice for commercial buildings, industrial facilities, high-rise apartments, pakhuzen, and other locations requiring reliable fire alarm capabilities and flow control.

UL/FM Fire Alarm Check Valve

Technyske spesifikaasjes

ParameterSpesifikaasje
Produkt Namme Alarm Check Valve / Fire Alarm Check Valve
Ferbining Type Flanged (YN 1092-2 PN10/PN16)
Operaasje Automatic (Pressure Differential)
Structure Type Butterfly / Check / Gate / Relief (Customizable)
Coating Fusion-Bonded Epoxy Coating (RAL3000 Red / Blue)
Craft Casting
OanpassingOEM, ODM
SertifisearringUL Listed, FM Approved, CE-sertifisearre
StandertYN 1902-2 PN10/PN16, UL 312, FM 1630

Wurkprinsipe

The alarm check valve operates on a simple yet reliable pressure differential principle:

1. Standby State (System Pressurized): The system side of the valve is filled with pressurized water. The clapper remains closed due to its own weight and the pressure balance between the supply side and system side.

2. Fire Event (Sprinkler Activation): When a fire occurs and the sprinkler head opens, water pressure on the system side drops. The pressure differential opens the clapper, allowing water to flow from the supply side into the system piping.

3. Alarm Activation: Simultaneously, water enters the alarm port through a small orifice, flowing to the water motor gong (audible alarm) and pressure switch (electrical signal to the fire control panel). The bypass check valve prevents false alarms from pressure surges.

UL/FM Fire Alarm Check Valve

Key Features

  1. High-Strength Ductile Iron Construction
  2. Integrated Alarm Activation – Dual Alarm Output
  3. UL, FM & CE Certified – Global Compliance
  4. Fusion-Bonded Epoxy Coating – Superior Corrosion Resistance
  5. Bypass Check Valve – False Alarm Prevention
  6. Wide Media Compatibility
  7. Flanged Connection – EN 1902-2 PN10/PN16

Applikaasjes

  1. Automatic Fire Sprinkler Systems
  2. Fire Pump Discharge Lines
  3. Industrial Fire Protection
  4. High-Rise Building Risers
  5. Municipal Fire Protection Networks

UL/FM Fire Alarm Check Valve

Ferpakking en ferstjoering

Ferpakking hinget ôf fan it produkttype en kwantiteit. Standard packing includes wooden cases with proper protection for flange faces and trim components. Ferstjoering kin wurde regele troch see, spoar, loft, of as per klant syn fersyk.

Betellingsbetingsten

T/T, L/C op sicht, Western Union & PayPal, ensfh.

Company Profile

Ien diel fan LUOYANG CAME ENERGY TECH CO., LTD is in profesjonele yndustriële fentyl leveransier, wijd oan it leverjen fan betroubere oplossings foar streamkontrôle foar brânbeskerming, HVAC, wetter behanneling, en yndustriële piping systemen wrâldwiid. Alle produkten wurde makke neffens ynternasjonale noarmen mei UL / FM, CE, en ISO 9001 sertifikaten. Mei oer 10 jierrenlange ûnderfining, in moderne foarsjenning fan 80,000 m², en 200+ profesjonele meiwurkers, wy tsjinje klanten yn 10+ lannen mei kwaliteitsprodukten, konkurrearjende prizen, en betroubere levering.

UL/FM Fire Alarm Check Valve

FAQ

Q1: What is the difference between an alarm check valve and a standard check valve?

IN: An alarm check valve is a specialized type of check valve; in addition to preventing backflow (like a standard check valve), it triggers an audible and visual alarm when water flows through the system. Standard check valves only prevent backflow and lack alarm functionality. Alarm check valves are primarily used in fire protection systems that require flow monitoring and alarm notification capabilities.

Q2: Which certification standards does this valve meet?

IN: This valve holds UL Listing (UL 312), FM Approval (FM 1630), and CE certification, meeting the strictest international safety and quality standards for fire protection equipment. These certifications ensure the product can be used in compliance with regulations for fire protection projects worldwide.

Q3: What is the function of the bypass check valve?

IN: The bypass check valve allows for slow, minor, and transient increases in supply pressure to pass through, thereby preventing false alarms caused by pressure fluctuations. It ensures that the alarm is triggered only when sprinkler heads actually activate and a sustained water flow occurs.