LUOYANG DAĦAL ENERĠIJA TECH CO, LTD

UL/FM Fire Alarm Check Valve | Korp tal-Ħadid Duttili | Fire Sprinkler System | DN50-DN300 | Ċċertifikat CE
PARAMETRI TAL-PRODOTT
| Materjal tal-Korp | Ħadid duttili (High-Strength) |
| Disc / Clapper Material | Ħadid duttili / Stainless Steel |
| Materjal tas-Siġill | PTFE (Polytetrafluoroethylene) / EPDM / NBR |
| Tip ta' Valv | Alarm Check Valve / Non-Return Valve |
| Firxa Daqs | Custom OEM (Tipiku: DN50 – DN300 / 2″ to 12″) |
| Pressjoni Nominali | PN10 / PN16 (IN 1902-2) |
| Firxa tat-Temperatura | Għoli, Medju, Baxx, Ambient |
| Midja | Ilma, Gass, Żejt, Acid, Base, and other fire extinguishing media |
Deskrizzjoni
Ħarsa ġenerali tal-prodott
The UL/FM Fire Alarm Check Valve is a specialized fire protection valve designed for wet-pipe automatic sprinkler systems. Constructed from high-strength ductile iron, it offers exceptional corrosion resistance and a long service life in demanding fire protection environments. It is an ideal choice for commercial buildings, faċilitajiet industrijali, high-rise apartments, warehouses, and other locations requiring reliable fire alarm capabilities and flow control.

UL/FM Fire Alarm Check Valve
Speċifikazzjonijiet Tekniċi
| Parametru | Speċifikazzjoni |
| Isem tal-Prodott | Alarm Check Valve / Fire Alarm Check Valve |
| Tip ta' Konnessjoni | Flanġ (IN 1092-2 PN10/PN16) |
| Operazzjoni | Automatic (Pressure Differential) |
| Structure Type | Butterfly / Check / Gate / Relief (Customizable) |
| Coating | Fusion-Bonded Epoxy Coating (RAL3000 Red / Blue) |
| Craft | Casting |
| Personalizzazzjoni | OEM, ODM |
| Ċertifikazzjoni | Elenkat UL, FM Approvat, Ċċertifikat CE |
| Standard | IN 1902-2 PN10/PN16, UL 312, FM 1630 |
Working Principle
The alarm check valve operates on a simple yet reliable pressure differential principle:
1. Standby State (System Pressurized): The system side of the valve is filled with pressurized water. The clapper remains closed due to its own weight and the pressure balance between the supply side and system side.
2. Fire Event (Sprinkler Activation): When a fire occurs and the sprinkler head opens, water pressure on the system side drops. The pressure differential opens the clapper, allowing water to flow from the supply side into the system piping.
3. Alarm Activation: Simultaneously, water enters the alarm port through a small orifice, flowing to the water motor gong (audible alarm) and pressure switch (electrical signal to the fire control panel). The bypass check valve prevents false alarms from pressure surges.

UL/FM Fire Alarm Check Valve
Karatteristiċi Ewlenin
- High-Strength Ductile Iron Construction
- Integrated Alarm Activation – Dual Alarm Output
- UL, FM & CE Certified – Global Compliance
- Fusion-Bonded Epoxy Coating – Superior Corrosion Resistance
- Bypass Check Valve – False Alarm Prevention
- Wide Media Compatibility
- Flanged Connection – EN 1902-2 PN10/PN16
Applikazzjonijiet
- Automatic Fire Sprinkler Systems
- Fire Pump Discharge Lines
- Industrial Fire Protection
- High-Rise Building Risers
- Municipal Fire Protection Networks

UL/FM Fire Alarm Check Valve
Ippakkjar u Ġarr
L-ippakkjar jiddependi mit-tip u l-kwantità tal-prodott. Standard packing includes wooden cases with proper protection for flange faces and trim components. Il-ġarr jista 'jiġi rranġat bil-baħar, ferrovija, arja, jew skont it-talba tal-klijent.
Termini ta' Ħlas
T/T, L/C fil-vista, Unjoni tal-Punent & PayPal, eċċ.
Profil tal-Kumpanija
LUOYANG CAME ENERGY TECH CO., LTD huwa fornitur professjonali tal-valv industrijali, dedicated to providing reliable flow control solutions for fire protection, HVAC, trattament tal-ilma, u sistemi ta 'pajpijiet industrijali madwar id-dinja. All products are manufactured to international standards with UL/FM, CE, u l-ISO 9001 ċertifikazzjonijiet. B'aktar minn 10 snin ta esperjenza, faċilità moderna ta 80,000 m², u 200+ impjegati professjonali, naqdu lill-klijenti fi 10+ pajjiżi bi prodotti ta’ kwalità, prezzijiet kompetittivi, u kunsinna affidabbli.

UL/FM Fire Alarm Check Valve
FAQ
Q1: What is the difference between an alarm check valve and a standard check valve?
A: An alarm check valve is a specialized type of check valve; in addition to preventing backflow (like a standard check valve), it triggers an audible and visual alarm when water flows through the system. Standard check valves only prevent backflow and lack alarm functionality. Alarm check valves are primarily used in fire protection systems that require flow monitoring and alarm notification capabilities.
Q2: Which certification standards does this valve meet?
A: This valve holds UL Listing (UL 312), FM Approval (FM 1630), and CE certification, meeting the strictest international safety and quality standards for fire protection equipment. These certifications ensure the product can be used in compliance with regulations for fire protection projects worldwide.
Q3: What is the function of the bypass check valve?
A: The bypass check valve allows for slow, minor, and transient increases in supply pressure to pass through, thereby preventing false alarms caused by pressure fluctuations. It ensures that the alarm is triggered only when sprinkler heads actually activate and a sustained water flow occurs.

UL/FM Fire Alarm Check Valve
ITLOB KOTAZZJONI
PRODOTTI RELATATI

Konnessjoni tad-Dipartiment tan-Nar Siamese Valve | Ħadid duttili | Ċertifikat UL/CE | 6″ Żbokk | Protezzjoni tan-Nar

Wafer Dual Plate Check Valve | Duplex Stainless Steel F51/F53 | API 594 | 150LB | Ilma baħar & Chemical Resistant

Grooved Butterfly Valve | Manual Signal Type with EPDM Coated Disc | Fire Protection System | DN50-DN300

Stainless Steel Swing & Lift Check Valve | 304/316L | Threaded Non Return Valve | 1/2″-12″ | Ċċertifikat CE

Cast Iron Swing Check Valve | Flanged Non Return Valve DN50-DN600 | PN10/PN16 | BS EN 12334

OS&Y Flanġ Valv Bieb Reżiljenti | UL/FM | Protezzjoni tan-Nar
- Email: sales@pipesandfittings.net
- WeChat: +86 18337900677





