LUOYANG CAME ENERGY TECH CO., LTD

UL/FM Fire Alarm Check Valve | Duktile Eisen Kierper | Feier Sprinkler System | DN50-DN300 | CE zertifizéiert
PRODUIT PARAMETER
| Kierper Material | Duktil Eisen (High-Strength) |
| Disc / Clapper Material | Duktil Eisen / Edelstol |
| Seal Material | PTFE (Polytetrafluoroethylene) / EPDM / NBR |
| Ventil Typ | Alarm Kontrollventil / Non-Return Valve |
| GrĂ©isst Range | OEM BenotzerdefinĂ©iert (Typesch: DN50 â DN300 / 2âł to 12âł) |
| Nominell Drock | PN 10 / PN 16 (IN 1902-2) |
| Temperaturbereich | Héich, Mëttelméisseg, Niddereg, Ambient |
| Medien | Waasser, Gas, Ueleg, Acid, Base, and other fire extinguishing media |
Beschreiwung
Produit Iwwersiicht
The UL/FM Fire Alarm Check Valve is a specialized fire protection valve designed for wet-pipe automatic sprinkler systems. Constructed from high-strength ductile iron, it offers exceptional corrosion resistance and a long service life in demanding fire protection environments. It is an ideal choice for commercial buildings, industrial facilities, high-rise apartments, warehouses, and other locations requiring reliable fire alarm capabilities and flow control.

UL/FM Fire Alarm Check Valve
Technesch Spezifikatioune
| Parameter | Spezifizéierung |
| Produit Numm | Alarm Kontrollventil / Fire Alarm Check Valve |
| Verbindung Typ | Geflanzt (IN 1092-2 PN10/PN16) |
| Operatioun | Automatic (Pressure Differential) |
| Structure Type | Butterfly / Check / Gate / Relief (Customisable) |
| Beschichtung | Fusion-Bonded Epoxy Beschichtung (RAL3000 Red / Blue) |
| Craft | Casting |
| Customization | OEM, ODM |
| Zertifikatioun | UL Listed, FM Approved, CE zertifizéiert |
| Standard | IN 1902-2 PN10/PN16, UL 312, FM 1630 |
Working Principle
The alarm check valve operates on a simple yet reliable pressure differential principle:
1. Standby State (System Pressurized): The system side of the valve is filled with pressurized water. The clapper remains closed due to its own weight and the pressure balance between the supply side and system side.
2. Fire Event (Sprinkler Activation): When a fire occurs and the sprinkler head opens, water pressure on the system side drops. The pressure differential opens the clapper, allowing water to flow from the supply side into the system piping.
3. Alarm Activation: Simultaneously, water enters the alarm port through a small orifice, flowing to the water motor gong (audible alarm) and pressure switch (electrical signal to the fire control panel). The bypass check valve prevents false alarms from pressure surges.

UL/FM Fire Alarm Check Valve
Schlëssel Fonctiounen
- High-Strength Ductile Iron Construction
- Integrated Alarm Activation â Dual Alarm Output
- UL, FM & CE Certified â Global Compliance
- Fusion-Bonded Epoxy Coating â Superior Corrosion Resistance
- Bypass Check Valve â False Alarm Prevention
- Wide Media Compatibility
- Flanged Connection â EN 1902-2 PN10/PN16
Uwendungen
- Automatic Fire Sprinkler Systems
- Fire Pump Discharge Lines
- Industrial Fire Protection
- High-Rise Building Risers
- Municipal Fire Protection Networks

UL/FM Fire Alarm Check Valve
Verpakung a Versand
D'Verpakung hÀnkt vun der Produktart an der Quantitéit of. Standard packing includes wooden cases with proper protection for flange faces and trim components. Sendung kann iwwer Mier arrangéiert ginn, Eisebunn, loft, oder no Ufro vum Client.
Bezuelen Konditiounen
T/T, L/C op Siicht, Western Union & PayPal, etc.
Firma Profil
LUOYANG CAME ENERGY TECH CO., LTD ass e professionnelle industrielle Ventil Supplier, gewidmet fir zouverlĂ€sseg FlowkontrolllĂ©isungen fir Feierschutz ze liwweren, HVAC, Waasser Behandlung, an industriell PĂ€if Systemer weltwĂ€it. All Produkter gi mat internationale Standards mat UL / FM hiergestallt, CE, an ISO 9001 ZertifizĂ©ierungen. Mat iwwer 10 Joer Erfahrung, eng modern Ariichtung vun 80,000 mÂČ vun, an 200+ berufflech Mataarbechter, mir dĂ©ngen Clienten an 10+ LĂ€nner mat QualitĂ©itsprodukter, kompetitiv PrĂ€isser, an zouverlĂ€sseg Liwwerung.

UL/FM Fire Alarm Check Valve
FAQ
Q1: What is the difference between an alarm check valve and a standard check valve?
A: An alarm check valve is a specialized type of check valve; in addition to preventing backflow (like a standard check valve), it triggers an audible and visual alarm when water flows through the system. Standard check valves only prevent backflow and lack alarm functionality. Alarm check valves are primarily used in fire protection systems that require flow monitoring and alarm notification capabilities.
Q2: Which certification standards does this valve meet?
A: This valve holds UL Listing (UL 312), FM Approval (FM 1630), and CE certification, meeting the strictest international safety and quality standards for fire protection equipment. These certifications ensure the product can be used in compliance with regulations for fire protection projects worldwide.
Q3: What is the function of the bypass check valve?
A: The bypass check valve allows for slow, minor, and transient increases in supply pressure to pass through, thereby preventing false alarms caused by pressure fluctuations. It ensures that the alarm is triggered only when sprinkler heads actually activate and a sustained water flow occurs.

UL/FM Fire Alarm Check Valve
Ufro engem ZITAT
Zesummenhang PRODUITEN

Swing Check Valve | Flanged Enden | Metal SĂ«tzen | WCB/SS304/SS316 | 2âł-24âł | Klass 150-900 | Ueleg & Gas, Waasser, Industriell

Grooved Butterfly Valve | Manual Signal Type with EPDM Coated Disc | Feier Schutz System | DN50-DN300

Goss Swing Check Valve | Flanged Net Retour Krunn DN50-DN600 | PN10/PN16 | BS EN 12334

Edelstol Swing & Lift Check Valve | 304/316L | Threaded Non Return Valve | 1/2âł-12âł | CE zertifizĂ©iert

Wafer Dual Plate Check Valve | Duplex Stainless Steel F51/F53 | API 594 | 150LB | Mierwaasser & Chemesch resistent

Pompjeesbau Verbindung Siamese Ventil | Duktil Eisen | UL/CE zertifizéiert | 6ⳠOutlet | Feier Schutz
- E-Mail: sales@pipesandfittings.net
- WeChat: +86 18337900677